The picture may show a similar product.
Part No.: 33631 000A
QUADRON 185Power Speed
NH in-line switch-disconnector-fuse size 1
connection top M12
double-breaking
operator independent switching (snap-action mechanism)
for busbars 30, 40, 60, 80, 100, 120 x 10
accessory required for busbar mounting
phase-out product
date of phase-out: 31.03.2026
System
185Power
Advantages of the product
When the cover is open, all touchable parts are voltage-free
Operator-independent switching
Lockable cover with double-bit lock
Mixed installation with all components 185Power
Can be sealed when switched on or off
Can be locked with up to 3 padlocks when switched off
| Product group | 18 |
| Subgroup | 53 |
| pack size | 1 |
| EAN | 4021267336318 |
| ECLASS 14.0 | 27142108 |
| ETIM 5.0 | EC001046 |
| ETIM 8.0 | EC001046 |
| ETIM 10.0 | EC001046 |
Standards
IEC 60947-1:2020
IEC 60947-3:2020 AC ratings only
Approvals
IEC (CB)
type number: QS185-1
EAC Type: NH
| for fuse links size: | NH 1 |
| fuse links acc. to standard: | IEC / HD 60269-2 |
| permitted power dissipation of the fuse-link: | 32 W |
| requirements for contact parts: |
Fuse links with silver-plated contact pieces recommended. For fuse links with nickel-plated contact pieces, a reduction factor of 0.8 is to be observed. |
| Details IEC | |
| Standards | |
|
IEC 60947-1:2020 IEC 60947-3:2020 AC ratings only |
| Electrical data IEC | |
| rated current (IEC): | 250 A |
| rated voltage (IEC) AC: | 800 V |
| rated voltage (IEC) DC: | 800 V |
| rated isolation voltage Ui AC: | 1000 V |
| rated isolation voltage Ui DC: | 1000 V |
| rated surge voltage Uimp : | 12 kV |
| Utilisation category AC (IEC 60947-3) : | AC-23B (690 V / 250 A) |
| cond. short-circuit current with fuses (AC): | 50 kA / 800 V (160 A) |
| 100 kA / 690 V (250 A) | |
| 120 kA / 500 V (250 A) | |
| approved wth fuse links of operation class: | gG |
| short-circuit strength when protected by fuses: | 120 kA |
power dissipation of the article:
The power dissipation at a typical load of 80 % results to 51,2 W.
(The power dissipation at full load would be 80,0 W.)
| Supplementary data IEC | |
|
The following values have been verified with tests under certain conditions. Please ask Wöhner for this conditions before designing your panel. |
| further utilisation category DC (IEC 60947-3): | DC-20B max. voltage between the fuses: 1000 V visible information required: Do not switch under load. |
| A fuse-combination unit acc. to IEC 60947-3 can only be operated at a higher voltage than its rated voltage, if it is used as a fuse-disconnector without breaking capacity, up to its max. rated insulation voltage and labelled as such. |
| min. permitted operation temperature | -25°C |
| max. permitted operation temperature | 55°C |
| min. permitted temperature for transport and storage | -25°C |
| The use of knife links is not permitted. The rated values specified in this product description apply exclusively to the use of fuses. | |
| distance to grounded parts = 0mm at 120kA | |
| Special operating conditions corresponding to IEC / EN 61439-1 may yield to foulty activations of pilot switches and fuse monitors. The operating conditions have to be considered for the analysis of status signals. | |
| Degree of protection IP30 at front, degree of protection near terminal depends on installation |
| Mechanical data | |
| W x H x D: | 100 x 781 x 274 |
| weight: | 1194,0 kg/100 |
| for busbars: | 30, 40, 60, 80, 100, 120 x 10 |
| CT can be integrated in the device: | ja |
| CT can be integrated in the CT module: | ja |
| front degree of protection: | IP30 |
| Terminal points | |
| screw connection | |
| Material properties | |
| halogen-free: | Yes |
| A fuse-combination unit acc. to IEC 60947-3 can only be operated at a higher voltage than its rated voltage, if it is used as a fuse-disconnector without breaking capacity, up to its max. rated insulation voltage and labelled as such. | |
|
Montageset erforderlich, siehe Zubehör |
|
| permitted power dissipation of the fuse-link: | 32 W |
| requirements for contact parts: |
Fuse links with silver-plated contact pieces recommended. For fuse links with nickel-plated contact pieces, a reduction factor of 0.8 is to be observed. |
33650
000A
mounting set with 3 bolts
for busbar connection on drilled busbars, including positioner
size 1 - 3
More
33651
000A
mounting set with 3 terminal clamps
for drill-less mounting on the busbar system, with and without CrossLink® touch-safe protection covers
size 1 - 3
for: QS185-...
More
33652
000A
insulated screw extension for terminal clamp
for safe live working with standard tools
size 1 - 3
More
33648
000A
connection set box terminal 70 mm² - 240 mm²
including rear cover
size 1 - 3
More
33649
000A
connection set box terminal 120 mm² - 300 mm²
including rear cover
size 1 - 3
More
33733
000A
terminal compartment cover
universal for NH-rails size 1 - 3 and connection rail 800 A
size 1- 3
More
33758
000A
lateral bearing strip
for front covers
size 00 - 3
More
33113
000
lateral cover support
for front covers
size 00 - 3
More
33647
000A
rear cover for terminal compartment cover
size 1 - 3
More
33642
000A
pilot switch
changeover 250 V AC / 5 A, 30 V DC / 4 A
QUADRON®185Power Speed size 00, 1, 2, 3
More
33762
000A
universal current transformer module
for mounting in the connection compartment
size 1 - 3
More
37277
000A
measuring transformer 200 A / 333 mV
size CT1
class 1
More
37279
000A
measuring transformer 400 A / 333 mV
size CT1
class 1
More
37278
000A
measuring transformer 250 A / 333 mV
size CT1
class 1
More
37287
000A
measuring transformer 400 A / 333 mV
size CT1
class 0.5s
More
37288
000A
measuring transformer 500 A / 333 mV
size CT1
class 0.5s
More
37285
000A
measuring transformer 200 A / 333 mV
size CT1
class 0.5s
More
37281
000A
measuring transformer 200 A / 333 mV
size CT1
class 0.5
More
37282
000A
measuring transformer 250 A / 333 mV
size CT1
class 0.5
More
37286
000A
measuring transformer 250 A / 333 mV
size CT1
class 0.5s
More
37283
000A
measuring transformer 400 A / 333 mV
size CT1
class 0.5
More
37280
000A
measuring transformer 500 A / 333 mV
size CT1
class 1
More
37284
000A
measuring transformer 500 A / 333 mV
size CT1
class 0.5
More
37200
000A
current transformer 200 A / 5 A
size CT1
1.5 VA / class 1
More
37201
000A
current transformer 250 A / 5 A
size CT1
1.5 VA / class 1
More
37202
000A
current transformer 400 A / 5 A
size CT1
1.5 VA / class 1
More
37203
000A
current transformer 500 A / 5 A
size CT1
1.5 VA / class 1
More
37204
000A
current transformer 200 A / 5 A
size CT1
1.5 VA / class 0.5
More
37205
000A
current transformer 250 A / 5 A
size CT1
1.5 VA / class 0.5
More
37206
000A
current transformer 400 A / 5 A
size CT1
1.5 VA / class 0.5
More
37207
000A
current transformer 500 A / 5 A
size CT1
1.5 VA / class 0.5
More
37208
000A
current transformer 200 A / 5 A, with decl. of conformity
size CT1
1.5 VA / class 0.5
stock sale
More
37209
000A
current transformer 250 A / 5 A, with decl. of conformity
size CT1
1.5 VA / class 0.5
More
37210
000A
current transformer 400 A / 5 A, with decl. of conformity
size CT1
1.5 VA / class 0.5
More
37211
000A
current transformer 500 A / 5 A, with decl. of conformity
size CT1
1.5 VA / class 0.5
More
Find your contact
to the contact site
Wöhner GmbH & Co. KG
Elektrotechnische Systeme
Mönchrödener Str. 10
96472 Rödental
Order hotline (Germany)
+49 9563 751 161
order@woehner.de
Technical hotline (Germany)
+49 9563 751 260
support@woehner.com