holder for cylindrical fuses

The picture may show a similar product.

Description

Part No.: 31118 200

AMBUS Panel

holder for cylindrical fuses

for mounting rail

Difference:Großverpackung

System

Panel

Product group 17
Subgroup 09
pack size 56
EAN 4021267151218
ETIM 5.0 EC002705
ETIM 8.0 EC002705

Approvals

Standards

IEC 60947-1:2020
IEC 60947-3:2020 AC ratings only

UL 4248-1

Approvals

CSA , UL , CCC

for UL feeder circuits >250V

type number: AES14x51

EAC Type: AES

UL file: E230163, UL category (for USA): IZLT https://www.ul.com

UL file: E230163, UL category (for Canada): IZLT7 https://www.ul.com

CCC certificate: 2004010302117255

Technical data

for fuse links size: 14x51
fuse links acc. to standard: IEC / HD 60269-2
permitted power dissipation of the fuse-link: 5 W
Details IEC
Standards
IEC 60947-1:2020
IEC 60947-3:2020 AC ratings only
Electrical data IEC
rated current (IEC): 50 A
rated voltage (IEC) AC: 690 V
rated isolation voltage Ui AC: 800 V
rated surge voltage Uimp : 6 kV
cond. short-circuit current with fuses (AC): 100 kA / 400 V (50 A)
100 kA / 500 V (40 A)
80 kA / 690 V (25 A)
approved wth fuse links of operation class: gG
Supplementary data IEC

The following values have been verified with tests under certain conditions. Please ask Wöhner for this conditions before designing your panel.

A fuse-combination unit acc. to IEC 60947-3 can only be operated at a higher voltage than its rated voltage, if it is used as a fuse-disconnector without breaking capacity, up to its max. rated insulation voltage and labelled as such.
min. permitted operation temperature -40°C
Details UL
Standards
UL 4248-1
for UL feeder circuits >250V
suitable for field-installed conductors
Electrical data UL
rated current (UL): 50 A
rated voltage (UL) AC: 600 V
rated frequency (UL): 50 / 60 Hz
rated voltage (UL) DC: 600 V
for wires UL: Cu 75°C
SCCR: 100 kA
Mechanical data
W x H x D: 81 x 90 x 69
weight: 30,4 kg/100
poles: 3-pole
Mounting: for mounting rail
degree of protection: IP20
front degree of protection: IP20
Terminal points
cage clamp connection
screw drive: PZ2
wire stripping: 14 mm
min. cross-section: 1,5 mm²
max. cross-section: 35 mm²
Md min.: 2,5 Nm
Md max.: 3,0 Nm
Not suitable for aluminium cables !
  
min. cross-section UL: AWG 14
max. cross-section UL: AWG 2
torque (UL): 26 lb-in
for wires UL: Cu 75°C
Material properties
halogen-free: Yes

Application notes

Not suitable for aluminium cables !
A fuse-combination unit acc. to IEC 60947-3 can only be operated at a higher voltage than its rated voltage, if it is used as a fuse-disconnector without breaking capacity, up to its max. rated insulation voltage and labelled as such.
permitted power dissipation of the fuse-link: 5 W
for UL feeder circuits >250V

Links (Prices, CAD data)

Downloads

Find your contact

to the contact site

Wöhner GmbH & Co. KG
Elektrotechnische Systeme
Mönchrödener Str. 10
96472 Rödental

Order hotline (Germany)
+49 9563 751 161
order@woehner.de

Technical hotline (Germany)
+49 9563 751 260
support@woehner.com