busbar adapter 25 A (32650)

The picture may show a similar product.

Description

Part No.: 32650000

EQUES®60Classic

busbar adapter 25 A

for direct starter Siemens S00 with spring terminal connection

45 x 200, with 165 mm long leads AWG 12 (4 mm²)

for busbars 12, 15, 20, 25, 30 x 5, 10 and section busbars

System

60Classic

Advantages of the product

Leitungsenden ultraschallverdichtet.
Rastmechanismus beim Aufschieben auf die Sammelschiene.
Extra lange Leitungen für die Cage-Clamp-Anschlüsse

Product group 05
Subgroup 21
pack size 4
EAN 4021267326500
ECLASS 6.1 27370304
ECLASS 7.1 27370304
ETIM 4.0 EC001531
ETIM 5.0 EC001531

Approvals

Standards

IEC 61439-1:2020

UL 508

Approvals

CSA , UL , DNV GL

for UL feeder circuits >250V

type number: EEC6025-L

UL file: E123577, UL category (for USA): NMTR https://www.ul.com

UL file: E123577, UL category (for Canada): NMTR7 https://www.ul.com

CSA file: 110285, CSA class: 3211-37 https://directories.csa-international.org

CCC approval: no certification required

Technical data

Details IEC
Standards
IEC 61439-1:2020
Electrical data IEC
rated current (IEC): 25 A
rated voltage (IEC) AC: 690 V
rated isolation voltage Ui AC: 800 V
rated surge voltage Uimp : 6 kV

power dissipation of the article:

The power dissipation at a typical load of 80 % results to 1,2 W.

(The power dissipation at full load would be 1,9 W.)

Details UL
Standards
UL 508
for UL feeder circuits >250V
Electrical data UL
rated current (UL): 25 A
rated voltage (UL) AC: 600 V
rated frequency (UL): 50 / 60 Hz
SCCR unprotected max.: 5 kA
3 cycles (without OPD) @ 600 V AC
SCCR protected max.: 65 kA
SCCR: 30 kA with 3RV20 12,5 A / 600 V AC
65 kA with 3RV20 16 A / 480 V AC
65 kA with 3RV20 25 A / 480 V AC
50 kA with 3RV20 32 A / 480 V AC
Mechanical data
W x H x D: 45 x 200 x 63
weight: 33,0 kg/100
poles: 3-pole
for busbars: 12, 15, 20, 25, 30 x 5, 10 and section busbars
Terminal points
with leads
AWG12 (4 mm²)
wire stripping: 9 mm

Application notes

There must be a clearance of at least 12 mm above the article to remove it from the busbar system.
short-circuit withstandability: the short-circuit capacity of the combination of adapter and motor starter depends on the motor starter
for UL feeder circuits >250V

Links

Downloads

Accessories

32963000
side-mounted module for busbar adapters
attachable to both sides
9 x 200
for: EEC60..
More

Find your contact

to the contact site

Wöhner GmbH & Co. KG
Elektrotechnische Systeme
Mönchrödener Str. 10
96472 Rödental

Order hotline (Germany)
+49 9563 751 161
order@woehner.de

Technical hotline (Germany)
+49 9563 751 260
support@woehner.com