Company
Innovations
Products
The picture may show a similar product.
Part No.: 01014 000A
CRITO®CrossBoard
connection terminal plate, 3-pole
lam. Cu. 20 - 32 x 3 - 15
connection top or bottom
NEW
System
CrossBoard® 800 A
Advantages of the product
also rigid copper busbars can be connected if they are installed without mechnical tension
| Product group | 07 |
| Subgroup | 51 |
| pack size | 1 |
| EAN | 4021267010140 |
| ECLASS 6.1 | 27141146 |
| ECLASS 7.1 | 27141146 |
| ETIM 4.0 | EC000001 |
| ETIM 5.0 | EC000001 |
Standards
IEC 61439-1:2020
IEC 60999-1:1999
IEC 60999-2:2003
UL 508
Approvals
UL
for UL feeder circuits >250V
type number: CR-F-173-F
CCC approval: no certification required
| Details IEC | |
| Standards | |
|
IEC 61439-1:2020 IEC 60999-1:1999 IEC 60999-2:2003 |
| Electrical data IEC | |
| rated current (IEC): | 630 A |
| rated voltage (IEC) AC: | 690 V |
| rated isolation voltage Ui AC: | 1000 V |
| rated surge voltage Uimp : | 6 kV |
| rated peak withstand current Ipk max.: | 80 kA |
| rated short-time withstand current Icw (1.0 s) max.: | 30 kA |
| Supplementary data IEC | |
|
The following values have been verified with tests under certain conditions. Please ask Wöhner for this conditions before designing your panel. |
| max. permitted voltage (IEC) AC: | 1000 V |
| max. permitted voltage (IEC) DC: | 1000 V |
| Details UL | |
| Standards | |
| UL 508 |
| for UL feeder circuits >250V | |
| suitable for field-installed conductors |
| Electrical data UL | |
| rated current (UL): | 600 A |
| rated voltage (UL) AC: | 600 V |
| rated frequency (UL): | 50 / 60 Hz |
| rated voltage (UL) DC: | 600 V |
| for wires UL: | Cu 75°C |
| SCCR unprotected max.: | 30 kA |
| 3 cycles (without OPD) @ 725 V AC | |
| SCCR protected max.: | 65 kA |
| SCCR: | 65 kA with any DIVQ/7 circuit breaker 800 A / 480 V AC |
| Mechanical data | |
| W x H x D: | 173 x 200 x 118 |
| weight: | 144,7 kg/100 |
| poles: | 3-pole |
| front degree of protection: | IP30 |
| Terminal points | |
| screw clamp connection | |
| screw drive: | S8 |
| wire stripping: | 38 mm |
| Md min.: | 18,0 Nm |
| Md max.: | 20,0 Nm |
| Not suitable for aluminium cables ! | |
| lam. Cu width: | 20 - 32 mm |
| lam. Cu thickness: | 3 - 15 mm |
| number of lam. Cu: | 1 |
| torque (UL): | 177 lb-in |
| for wires UL: | Cu 75°C |
| Not suitable for aluminium cables ! | |
| The insulation performance of the article depends on the installation conditions. | |
| for UL feeder circuits >250V |
Find your contact
to the contact site
Wöhner GmbH & Co. KG
Elektrotechnische Systeme
Mönchrödener Str. 10
96472 Rödental
Order hotline (Germany)
+49 9563 751 161
order@woehner.de
Technical hotline (Germany)
+49 9563 751 260
support@woehner.com