Company
Innovationen
Products
На фотографии может быть изображена аналогичная статья.
Арт.: 33505000
QUADRON®Panel Speed
Выключатель-разъединитель нагрузки с предохранителями 3-полюсный
Рамная клемма, для соединения с поворотной рукояткой двери
Типоразмер 00
double-breaking
operator independent switching (snap-action mechanism)
for mounting plate
Система
Panel
Преимущества продукта
With spring-controlled switch mechanism for frequent switching as per utilisation category "A"
FLAG indicator shows the switch setting
Fuses can be changed safely and without tools thanks to double-breaking main contacts
Additional visible separating section by removing the cover incl. fuses
Can be used as mains disconnector as per IEC / EN 60204-1 (main switch)
Also as an Emergency Off switch in combination with the red-yellow door coupling twist handle
Main switch and Emergency Off only in combination with AC-23A/B
Switches can be installed 90° left/right horizontal, always with the same switch lug position
Группа продуктов | 15 |
Подгруппа | 03 |
Кол-во | 1 |
EAN | 4021267335052 |
ECLASS 6.1 | 27371401 |
ECLASS 7.1 | 27371401 |
ETIM 4.0 | EC001040 |
ETIM 5.0 | EC001040 |
Стандарты
IEC 60947-1:2020
IEC 60947-3:2020 AC ratings only
номер типа: QCS-NH00
для предохранителей размера: | NH 000, NH 00 |
предохранители в соответствии со стандартом: | IEC / HD 60269-2 |
допустимая мощность рассеивания плавкой вставки: | 10 W |
requirements for contact parts: |
Fuse links with silver-plated contact pieces recommended. For fuse links with nickel-plated contact pieces, a reduction factor of 0.8 is to be observed. |
Подробности IEC | |
Стандарты | |
IEC 60947-1:2020 IEC 60947-3:2020 AC ratings only |
Электрические данные IEC | |
Номинальный ток (IEC): | 125 A |
номинальное напряжение (IEC) AC: | 690 В |
номинальное напряжение изоляции U i AC: | 800 В |
номинальное импульсное напряжение U imp : | 8 kV |
Катагория применения AC: | AC-23B (690V/125A) AC-23A (500V/125A) AC-22A (690V/125A) |
Категория применения DC: | 2 current paths (L1,L3) in series DC-22B (220V/125A) 3 current paths in series DC-22B (440V/63A) |
cond. short-circuit current with fuses (AC): | 50 kA / 690 V (125A) |
одобрено с плавкими вставками рабочего класса: | gG |
Fuses gL/gG, size 00, 690V/125A for fuse links IEC 60269-2 / DIN VDE 0636-2 size 00 up to 10W power dissipation | |
Special operating conditions corresponding to IEC / EN 61439-1 may yield to foulty activations of pilot switches and fuse monitors. The operating conditions have to be considered for the analysis of status signals. | |
When several devices are used side-by-side in continuous operation, the rated load factor specified in VDE 0660 Part 500 / EN 60 439-1, Table 1, must be observed. | |
System component: degree of protection IP20 at front as per DIN EN 60529, dependent upon installation in the connection area; shock protection to DIN EN 50274 |
Механические данные | |
Ш x В x Г: | 106 x 233 x 153 |
Вес: | 201,6 kg/100 |
Полюсность: | 3-пол. |
Mounting: | for mounting plate |
Особенности клеммной техники | |
Not suitable for aluminium cables ! | |
Box terminal: |
Not suitable for aluminium cables ! | |
допустимая мощность рассеивания плавкой вставки: | 10 W |
requirements for contact parts: |
Fuse links with silver-plated contact pieces recommended. For fuse links with nickel-plated contact pieces, a reduction factor of 0.8 is to be observed. |
Find your contact
to the contact site
Wöhner GmbH & Co. KG
Elektrotechnische Systeme
Mönchrödener Str. 10
96472 Rödental
Order hotline (Germany)
+49 9563 751 161
order@woehner.de
Technical hotline (Germany)
+49 9563 751 260
support@woehner.com