L'Entreprise
Innovationen
Produits
The picture may show a similar product.
Référence 31925000AB
AMBUS®Panel
support pour fusibles cylindriques avec LED
Class J / 3P, borne à cage 50 mm²
60 A / 600 V (27x60)
for mounting rail
just data for box label (no technical data)
Difference:Fertigung in USA
Système
Panel
Avantages produit
large clamping range, also for two identical conductors (adjacent)
holder for label
with indicator for tripped fuse
any polarity for DC voltage applications
Groupe de produits | 16 |
Sous-groupe | 06 |
Dimensions de l'emballage | 2 |
EAN | 4021267319250 |
ECLASS 6.1 | 27142190 |
ECLASS 7.1 | 27142190 |
ETIM 4.0 | EC002705 |
ETIM 5.0 | EC002705 |
Normes
IEC 60269-1:2006 + A1:2009 + A2:2014
IEC 60269-2:2013 + A1:2016, Fuse system H
UL 4248-8
UL 4248-1
Approbations
CSA , UL
for UL feeder circuits >250V
Type: AJC60
UL file: E230163, UL category (for USA): IZLT https://www.ul.com
UL file: E230163, UL category (for Canada): IZLT7 https://www.ul.com
CSA file: 110285, CSA class: 6225-01 https://directories.csa-international.org
for fuse links size: | Class J 60 A |
fuse links acc. to standard: | UL 248-8 |
permitted power dissipation of the fuse-link: | 7 W |
Details IEC | |
Normes | |
IEC 60269-1:2006 + A1:2009 + A2:2014 IEC 60269-2:2013 + A1:2016, Fuse system H |
Electrical data IEC | |
min. operating voltage AC: | 110 V |
min. operating voltage DC: | 110 V |
power dissipation of the article:
The power dissipation at a typical load of 80 % results to 2,5 W.
(The power dissipation at full load would be 3,9 W.)
for Class J fuses 35 - 60A as per UL 248-8 (27x60) indicator light operating voltage range: 110 - 600 V AC / DC |
Details UL | |
Normes | |
UL 4248-8
UL 4248-1 |
for UL feeder circuits >250V | |
suitable for field-installed conductors |
Electrical data UL | |
rated current (UL): | 60 A |
rated voltage (UL) AC: | 600 V |
min. operating voltage AC: | 110 V |
rated frequency (UL): | 50 / 60 Hz |
rated voltage (UL) DC: | 600 V |
min. operating voltage DC: | 110 V |
for wires UL: | Cu 75°C |
Icc: | 200 kA |
Charactéristiques mécaniques | |
L x H x P: | 120 x 118 x 82 |
Poids: | 55,9 kg/100 |
Pôles: | 3 pôles |
Mounting: | for mounting rail |
degree of protection: | IP20 |
front degree of protection: | IP20 |
Points de raccordement | |
Not suitable for aluminium cables ! | |
min. cross-section UL: | AWG 14 |
max. cross-section UL: | AWG 1/0 |
for wires UL: | Cu 75°C |
for applications acc. to IEC / EN : |
Not suitable for aluminium cables ! | |
permitted power dissipation of the fuse-link: | 7 W |
for UL feeder circuits >250V |
Trouver votre contact
to the contact site
Wöhner GmbH & Co. KG
Elektrotechnische Systeme
Mönchrödener Str. 10
96472 Rödental
Order hotline (Germany)
+49 9563 751 161
order@woehner.de
Technical hotline (Germany)
+49 9563 751 260
support@woehner.com