in-line fuse switch-disconnector 400 A (37527)

The picture may show a similar product.

Description

Part No.: 37527000A

QUADRON®185Power

in-line fuse switch-disconnector 400 A

size 2, 1-pole switchable

V-clamp 120 mm²

terminal body alu, pressure piece brass

prewired with 3x measuring transformers 400 A / 333 mV, accuracy class 1, with lead RJ12 (3,00 m)

for busbars 30, 40, 60, 80, 100, 120 x 10

coming soon

System

185Power

Advantages of the product

Self-closing inspection holes are available in the cover.

Cover can be locked when closed.

Product group 12
Subgroup 64
pack size 1
EAN 4021267375270
ECLASS 6.1 27142108
ECLASS 7.1 27142108
ETIM 4.0 EC001046
ETIM 5.0 EC001046

Approvals

Standards

IEC 60947-1:2020
IEC 60947-3:2020 AC ratings only

Approvals

IEC (CB)

type number: QU185-2 Pre-Assembled

Technical data

for fuse links size: NH 2
fuse links acc. to standard: IEC / HD 60269-2
permitted power dissipation of the fuse-link: 34 W
requirements for contact parts: Fuse links with silver-plated contact pieces recommended.
For fuse links with nickel-plated contact pieces, a reduction factor of 0.8 is to be observed.
Details IEC
Standards
IEC 60947-1:2020
IEC 60947-3:2020 AC ratings only
Electrical data IEC
rated current (IEC): 400 A
rated voltage (IEC) AC: 800 V
rated isolation voltage Ui AC: 1000 V
rated surge voltage Uimp : 12 kV
Utilisation category AC (IEC 60947-3) :

AC-22B (800 V / 200 A)
AC-22B (690 V / 400 A)
AC-23B (400 V / 400 A)

Utilisation category DC (IEC 60947-3) : DC-20B
max. voltage between the fuses: 1000V
visible information required: Do not switch under load.
cond. short-circuit current with fuses (AC): 100 kA / 690 V (400 A)
120 kA / 400 V (400 A)
65 kA / 800 V (200A)
approved wth fuse links of operation class: gG

power dissipation of the article:

The power dissipation at a typical load of 80 % results to 38.4 W.

(The power dissipation at full load would be 60.0 W.)

Supplementary data IEC

The following values have been verified with tests under certain conditions. Please ask Wöhner for this conditions before designing your panel.

A fuse-combination unit acc. to IEC 60947-3 can only be operated at a higher voltage than its rated voltage, if it is used as a fuse-disconnector without breaking capacity, up to its max. rated insulation voltage and labelled as such.
Besondere Betriebsbedingungen gemäß IEC / EN 61439-1 können zu Fehlauslösungen von Meldeschaltern oder Sicherungsüberwachungen führen. Die vorliegenden Betriebsbedingungen sind dementsprechend bei der Auswertung der Meldesignale zu berücksichtigen.
Degree of protection IP20 at front, degree of protection near terminal depends on installation
Mechanical data
W x H x D: 100 x 687 x 189
weight: 543.0 kg/100
poles: 3-pole
for busbars: 30, 40, 60, 80, 100, 120 x 10
CT can be integrated in the device: ja
CT can be integrated in the CT module: nein
front degree of protection: IP20
degree of protection when open: IP10

Type of fastening:
can be screwed onto drilled busbar, diameter 13mm, undrilled mounting with terminal clamp
connection:
screw connection M12

Terminal points
v-clamp
min. cross-section: 25 mm²
max. cross-section: 240 mm²
re: 25 - 95 mm²
rm: 25 - 150 mm²
se: 35 - 240 mm²
sm: 35 - 185 mm²
Suitable for aluminium conductors.
the temperature of aluminium conductors must not exceed 80°C (see operating instructions)
pre-treatment of aluminium conductors: see general technical information (under Downloads)

Application notes

Suitable for aluminium conductors.
the temperature of aluminium conductors must not exceed 80°C (see operating instructions)
pre-treatment of aluminium conductors: see general technical information (under Downloads)
A fuse-combination unit acc. to IEC 60947-3 can only be operated at a higher voltage than its rated voltage, if it is used as a fuse-disconnector without breaking capacity, up to its max. rated insulation voltage and labelled as such.

Reference

The terminal compartment cover 33733 is always needed for the connection at top and when using cable lugs.

permitted power dissipation of the fuse-link: 34 W
requirements for contact parts: Fuse links with silver-plated contact pieces recommended.
For fuse links with nickel-plated contact pieces, a reduction factor of 0.8 is to be observed.

Links

Downloads

Accessories

33740000A
terminal clamp
for busbar systems without system covers
size 1 - 3
More

33733000A
terminal compartment cover
universal for NH-rails size 1 - 3 and connection rail 800 A
size 1- 3
More

33564000A
V-clamp
terminal body alu, pressure piece brass
for PEN
for Cu / Al 120 - 300 mm²
coming soon
More

33738000A
CrossLink® terminal clamp
for busbar systems with CrossLink® touch-safe protection
size 1 - 3
More

33156000
pilot switch
changeover 250 V AC / 5 A, 30 V DC / 4 A
More

33758000A
lateral bearing strip
for front covers
size 00 - 3
More

33558000A
V-clamp
without cover cap
terminal body alu, pressure piece brass
size 1-3
for Cu / Al 120 - 300 mm²
coming soon
More

Find your contact

to the contact site

Wöhner GmbH & Co. KG
Elektrotechnische Systeme
Mönchrödener Str. 10
96472 Rödental

Order hotline (Germany)
+49 9563 751 161
order@woehner.de

Technical hotline (Germany)
+49 9563 751 260
support@woehner.com