in-line fuse switch-disconnector 160 A (37525)

The picture may show a similar product.

Description

Part No.: 37525000B

QUADRON®185Power

in-line fuse switch-disconnector 160 A

Size 00, 1-pole switchable

high version with V-clamp 95 mm²

Klemmgehäuse Alu, Druckstück Messing

prewired with 3x measuring transformers 150 A / 333 mV, accuracy class 1, with 6-pole plug connection

for busbars 30, 40, 60, 80, 100, 120 x 10

coming soon

System

185Power

Advantages of the product

Self-closing inspection holes are available in the cover.

Cover can be locked when closed.

Product group 12
Subgroup 62
pack size 1
EAN 4021267375256
ECLASS 6.1 27142108
ECLASS 7.1 27142108
ETIM 4.0 EC001046
ETIM 5.0 EC001046

Approvals

Standards

IEC 60947-1:2020
IEC 60947-3:2020 AC ratings only

type number: QU185-00 Pre-Assembled

Technical data

for fuse links size: NH 000, NH 00
fuse links acc. to standard: IEC / HD 60269-2
permitted power dissipation of the fuse-link: 12 W
requirements for contact parts: Fuse links with silver-plated contact pieces recommended.
For fuse links with nickel-plated contact pieces, a reduction factor of 0.8 is to be observed.
Details IEC
Standards
IEC 60947-1:2020
IEC 60947-3:2020 AC ratings only
Electrical data IEC
rated current (IEC): 160 A
rated voltage (IEC) AC: 800 V
rated isolation voltage Ui AC: 1000 V
rated surge voltage Uimp : 8 kV
Utilisation category AC (IEC 60947-3) :

AC-23B 160A/400V
AC-22B 160A/500V

Utilisation category DC (IEC 60947-3) : DC-20B
max. voltage between the fuses: 1000V
visible information required: Do not switch under load.
cond. short-circuit current with fuses (AC): 30 kA / 800 V (63 A)
100 kA / 690 V
approved wth fuse links of operation class: gG

power dissipation of the article:

The power dissipation at a typical load of 80 % results to 17.9 W.

(The power dissipation at full load would be 28.0 W.)

Supplementary data IEC

The following values have been verified with tests under certain conditions. Please ask Wöhner for this conditions before designing your panel.

A fuse-combination unit acc. to IEC 60947-3 can only be operated at a higher voltage than its rated voltage, if it is used as a fuse-disconnector without breaking capacity, up to its max. rated insulation voltage and labelled as such.
Degree of protection IP20 at front, degree of protection near terminal depends on installation
Mechanical data
W x H x D: 50 x 687 x 189
weight: 298.0 kg/100
poles: 3-pole
for busbars: 30, 40, 60, 80, 100, 120 x 10
CT can be integrated in the device: ja
front degree of protection: IP20

Type of fastening:
can be screwed onto drilled busbar, undrilled mounting with terminal clamp
connection: V-Clamp

Terminal points
v-clamp
min. cross-section: 16 mm²
max. cross-section: 120 mm²
re: 16 - 95 mm²
rm: 16 - 95 mm²
se: 25 - 120 mm²
sm: 25 - 120 mm²
Suitable for aluminium conductors.
the temperature of aluminium conductors must not exceed 80°C (see operating instructions)
pre-treatment of aluminium conductors: see general technical information (under Downloads)

Application notes

Suitable for aluminium conductors.
the temperature of aluminium conductors must not exceed 80°C (see operating instructions)
pre-treatment of aluminium conductors: see general technical information (under Downloads)
A fuse-combination unit acc. to IEC 60947-3 can only be operated at a higher voltage than its rated voltage, if it is used as a fuse-disconnector without breaking capacity, up to its max. rated insulation voltage and labelled as such.
permitted power dissipation of the fuse-link: 12 W
requirements for contact parts: Fuse links with silver-plated contact pieces recommended.
For fuse links with nickel-plated contact pieces, a reduction factor of 0.8 is to be observed.

Links

Downloads

Accessories

33732000A
terminal compartment cover, high version, connection bottom
for 33700, 33715, 33720, 33770, 33771, 33772 and QUADRON®185Power Speed size 00
size 00
More

33739000A
terminal clamp
for busbar systems without system covers
size 00
More

33156000
pilot switch
changeover 250 V AC / 5 A, 30 V DC / 4 A
More

33113000
lateral cover support
for front covers
size 00 - 3
More

33758000A
lateral bearing strip
for front covers
size 00 - 3
More

33765000A
CrossLink® terminal clamp IP20
for busbar systems with touch-safe protection
size 00
More

Find your contact

to the contact site

Wöhner GmbH & Co. KG
Elektrotechnische Systeme
Mönchrödener Str. 10
96472 Rödental

Order hotline (Germany)
+49 9563 751 161
order@woehner.de

Technical hotline (Germany)
+49 9563 751 260