Part No.: 01203000
CRITO®
universal conductor terminal
16 - 120 mm², AWG 6 - 250 MCM
for busbars flat busbars 10 mm and section busbars
System
60Classic, 30Compact 3P, centre feed unit, 100Energy
Advantages of the product
Terminal with integrated holding spring, captive clamping screw and opened terminal space.
Indication of nominal cross-section and tightening torque noted on the terminal.
Product group | 07 |
Subgroup | 18 |
pack size | 25 |
EAN | 4021267012038 |
ECLASS 6.1 | 27141146 |
ECLASS 7.1 | 27141146 |
ETIM 4.0 | EC000001 |
ETIM 5.0 | EC000001 |
Standards
IEC 61439-1:2020
IEC 60999-1:1999
IEC 60999-2:2003
UL 508
Approvals
CSA , UL , DNV GL
type number: 528
UL file: E123577, UL category (for USA): NMTR2 https://www.ul.com
UL file: E123577, UL category (for Canada): NMTR8 https://www.ul.com
CSA file: 110285, CSA class: 3211-37 https://directories.csa-international.org
CCC approval: no certification required
Details IEC | |
Standards | |
IEC 61439-1:2020 IEC 60999-1:1999 IEC 60999-2:2003 |
Electrical data IEC | |
Rated current (IEC): | 250 A |
rated voltage (IEC) AC: | 800 V |
rated peak withstand current Ipk max.: | 62.8 kA |
rated short-time withstand current Icw (1.0 s) max.: | 20.8 kA |
power dissipation of the article:
The power dissipation at a typical load of 80 % results to 0.0 W.
(The power dissipation at full load would be 0.0 W.)
Supplementary data IEC | |
The following values have been verified with tests under certain conditions. Please ask Wöhner for this conditions before designing your panel. |
max. permitted voltage (IEC) AC: | 1000 V |
max. permitted voltage (IEC) DC: | 1500 V |
current capacity (IEC) max.: | 440 A |
Details UL | |
Standards | |
UL 508 |
suitable for field-installed conductors |
Electrical data UL | |
rated current (UL): | 255 A |
rated voltage (UL) AC: | 600 V |
rated frequency (UL): | 50 / 60 Hz |
Mechanical data | |
W x H x D: | 24 x 36 x 55 |
weight: | 10.9 kg/100 |
for busbars: | flat busbars 10 mm and section busbars |
Terminal points | |
min. cross-section: | 16 mm² |
max. cross-section: | 120 mm² |
Terminal space: | 17 x 15 |
Md min.: | 12.0 Nm |
Md max.: | 18.0 Nm |
Not suitable for aluminium cables ! | |
16 - 120 mm² / AWG 4 - MCM 250 |
Not suitable for aluminium cables ! | |
The insulation performance of the article depends on the installation conditions. | |
The suitability for feeder circuits (meeting the required feeder spacings) depends on the installation conditions. |
Find your contact
to the contact site
Wöhner GmbH & Co. KG
Elektrotechnische Systeme
Mönchrödener Str. 10
96472 Rödental
Order hotline (Germany)
+49 9563 751 161
order@woehner.de
Technical hotline (Germany)
+49 9563 751 260
support@woehner.com