changeover switch 3-pole (33898)

The picture may show a similar product.

Description

Part No.: 33898000A

CAPUS®Panel

changeover switch 3-pole

box terminal 16 - 50 mm² / AWG 6 - 1, graphite grey handle

125 A

for mounting plate or mounting rail

NEW

System

Mounting plate, DIN rail

Advantages of the product

lockable in 0-position with a padlock (max. 5 mm diameter)

Product group 14
Subgroup 32
pack size 1
EAN 4021267338985
ECLASS 6.1 27371403
ECLASS 7.1 27371403
ETIM 4.0 EC000216
ETIM 5.0 EC000216

Approvals

Standards

IEC 60947-1:2020
IEC 60947-3:2020 AC ratings only

UL 508

Approvals

UL

type number: CO-SD2-3-125

UL file: E506215, UL category (for USA): NLRV https://www.ul.com

UL file: E506215, UL category (for Canada): NLRV7 https://www.ul.com

Technical data

Details IEC
Standards
IEC 60947-1:2020
IEC 60947-3:2020 AC ratings only
Electrical data IEC
rated current (IEC): 125 A
rated voltage (IEC) AC: 690 V
rated frequency (IEC): 50 / 60 Hz
rated isolation voltage Ui AC: 800 V
rated surge voltage Uimp : 8 kV
Utilisation category AC (IEC 60947-3) : AC-23 A (690 V / 63 A)
AC-23 A (415 V / 100 A)
AC-22 A (690 V / 100 A)
AC-21 A (690 V / 100 A)
cond. short-circuit current with fuses (AC): 10 kA
approved wth fuse links of operation class: gG
rated short-time withstand current Icw (1.0 s) max.: 1.5 kA
rated making capacity: 3.5 kA

power dissipation of the article:

The power dissipation at a typical load of 80 % results to 6.0 W.

(The power dissipation at full load would be 9.3 W.)

Details UL
Standards
UL 508
Electrical data UL
rated current (UL): 125 A
rated voltage (UL) AC: 600 V
rated frequency (UL): 50 / 60 Hz
for wires UL: Cu 75°C
SCCR protected max.: 5 kA
5 kA with fuse max. 80 A / 600 V AC
Mechanical data
W x H x D: 104 x 100 x 80
weight: 53.0 kg/100
poles: 3-pole
Mounting: for mounting plate or mounting rail
degree of protection: IP20
Terminal points
cage clamp connection
screw drive: PZ2
wire stripping: 13 mm
min. cross-section: 16 mm²
max. cross-section: 50 mm²
Md min.: 3.5 Nm
Md max.: 3.5 Nm
Not suitable for aluminium cables !
  
min. cross-section UL: AWG 6
max. cross-section UL: AWG 1
torque (UL): 31 lb-in
for wires UL: Cu 75°C

all poles switched at the same time

Application notes

Not suitable for aluminium cables !

Links

Downloads

Accessories

33680000A
extension shaft, length 100 mm
for: SD1, SD2, SD3
More

33681000A
extension shaft, length 200 mm
for: SD1, SD2, SD3
More

33682000A
extension shaft, length 300 mm
for: SD1, SD2, SD3
More

33692000A
pilot switch
1 n/c + 1 n/o, screw terminal
for: SD1, SD2, SD3
More

33695000A
set connection space cover 3-pole
for: SD2-3, SD2-4
More

33684000A
CAPUS®Panel
Neutral Pole for SD2-3P switch-disconnector
box terminal 16 - 50 mm² / AWG 6 - 1
NEW
More

Find your contact

to the contact site

Wöhner GmbH & Co. KG
Elektrotechnische Systeme
Mönchrödener Str. 10
96472 Rödental

Order hotline (Germany)
+49 9563 751 161
order@woehner.de

Technical hotline (Germany)
+49 9563 751 260
support@woehner.com