Inovações
Produtos
A imagem pode mostrar um produto similar.
Código da peça: 31922 000
AMBUS®Panel
suporte para fusíveis cilíndricos
Class J / 3P, prensa-cabo 50 mm²
60 A / 600 V (27x60)
for mounting rail
Sistema
Panel
Vantagens do produto
large clamping range, also for two identical conductors (adjacent)
holder for label
| Grupo de produto | 16 |
| Subgroup | 06 |
| Unidade por pacote | 2 |
| EAN | 4021267319229 |
| ECLASS 6.1 | 27142190 |
| ECLASS 7.1 | 27142190 |
| ETIM 4.0 | EC002705 |
| ETIM 5.0 | EC002705 |
Standards
IEC 60269-1:2006 + A1:2009 + A2:2014
IEC 60269-2:2013 + A1:2016, Fuse system H
UL 4248-8
UL 4248-1
Approvals
CSA , UL
for UL feeder circuits >250V
Número de tipo: AJC60
UL file: E230163, UL category (for USA): IZLT https://www.ul.com
UL file: E230163, UL category (for Canada): IZLT7 https://www.ul.com
CSA file: 110285, CSA class: 6225-01 https://directories.csa-international.org
| for fuse links size: | Class J 60 A |
| fuse links acc. to standard: | UL 248-8 |
| permitted power dissipation of the fuse-link: | 7 W |
| Dados IEC | |
| Standards | |
|
IEC 60269-1:2006 + A1:2009 + A2:2014 IEC 60269-2:2013 + A1:2016, Fuse system H |
Electrical data
Dissipação de energia do artigo:
A dissipação de energia em uma carga de 80% resulta em 2,5 W.
(A dissipação de energia em sua carga máxima seria 3,9 W.)
| for Class J fuses 35 - 60A as per UL 248-8 (27x60) |
| Dados UL | |
| Standards | |
|
UL 4248-8
UL 4248-1 |
| for UL feeder circuits >250V | |
| suitable for field-installed conductors |
| Dados electricos UL | |
| corrente nominal (UL): | 60 A |
| rated voltage (UL) AC: | 600 V |
| rated frequency (UL): | 50 / 60 Hz |
| tensão nominal (UL) DC: | 600 V |
| for wires UL: | Cu 75°C |
| SCCR: | 200 kA |
| Dados mecânicos | |
| L x A x P: | 120 x 118 x 82 |
| Peso: | 55,9 kg/100 |
| Polaridade: | 3 polos |
| Montagem: | for mounting rail |
| degree of protection: | IP20 |
| front degree of protection: | IP20 |
| pontos terminais | |
| Not suitable for aluminium cables ! | |
| min. cross-section UL: | AWG 14 |
| max. cross-section UL: | AWG 1/0 |
| for wires UL: | Cu 75°C |
|
for applications acc. to IEC / EN : |
|
| Not suitable for aluminium cables ! | |
| permitted power dissipation of the fuse-link: | 7 W |
| for UL feeder circuits >250V | |
31360
000
fusível 35 A
-Mersen-
600 V AC, time delay
Class J, 27x60
Mais
31361
000
fusível 40 A
-Mersen-
600 V AC, time delay
Class J, 27x60
Mais
31362
000
fusível 45 A
-Mersen-
600 V AC, time delay
Class J, 27x60
Mais
31363
000
fusível 50 A
-Mersen-
600 V AC, time delay
Class J, 27x60
Mais
31364
000
fusível 60 A
-Mersen-
600 V AC, time delay
Class J, 27x60
Mais
31511
000A
fusível 35 A
-Mersen-
600 V AC, fast acting
Class J, 27x60
Mais
31512
000A
fusível 40 A
-Mersen-
600 V AC, fast acting
Class J, 27x60
Mais
31514
000A
fusível 50 A
-Mersen-
600 V AC, fast acting
Class J, 27x60
Mais
31515
000A
fusível 60 A
-Mersen-
600 V AC, fast acting
Class J, 27x60
Mais
Encontre sua pessoa de contato
Para a página de contato
Wöhner Sistemas
Eletrotécnicos Ltda.
Rua Antônio Galvão Pacheco, 185
18550-612, Boituva/SPl
Brasil
Linha direta de pedidos (Alemanha)
+49 9563 751 125
order@woehner.de
Linha direta de tecnologia (Alemanha)
+49 9563 751 508