chave seccionadora com fusíveis, 3 polos (33513)

A imagem pode mostrar um produto similar.

Descrição

Código da peça: 33513 000

QUADRON®60Classic Speed

chave seccionadora com fusíveis, 3 polos

Size NH 1

parafuso M10, conexão inferior, para manopla rotativa de acoplamento em porta

tamanho 1

double-breaking

operator independent switching (snap-action mechanism)

para barramentos 12, 15, 20, 25, 30 x 5, 10 e barramentos de seção

Sistema

60Classic

Vantagens do produto

With spring-controlled switch mechanism for frequent switching as per utilisation category "A"
FLAG indicator shows the switch setting
Fuses can be changed safely and without tools thanks to double-breaking main contacts
Additional visible separating section by removing the cover incl. fuses
Can be used as mains disconnector as per IEC / EN 60204-1 (main switch)
Also as an Emergency Off switch in combination with the red-yellow door coupling twist handle

CrossLink® adapter technology
Simple and safe clicking into place and making contact
Busbar supports can be mounted above each other for flat busbars

Switched can be installed 90° left/right horizontal, always with the same switch lug position

Grupo de produto 15
Subgroup 23
Unidade por pacote 1
EAN 4021267335137
ECLASS 6.1 27371401
ECLASS 7.1 27371401
ETIM 4.0 EC001040
ETIM 5.0 EC001040
ETIM 8.0 EC001040

Aprovações

Standards

IEC 60947-1:2020
IEC 60947-3:2020 AC ratings only

Approvals

IEC (CB) , VDE , DNV GL

Número de tipo: QCS-NH1

Dados técnicos

for fuse links size: NH 1
fuse links acc. to standard: IEC / HD 60269-2
permitted power dissipation of the fuse-link: 23 W
requirements for contact parts: Fuse links with silver-plated contact pieces recommended.
For fuse links with nickel-plated contact pieces, a reduction factor of 0.8 is to be observed.
Dados IEC
Standards
IEC 60947-1:2020
IEC 60947-3:2020 AC ratings only
Dados elétricos IEC
Corrente de medição (IEC): 250 A
Tensão de medição (IEC) AC: 690 V
Tensão nominal de isolamento: 800 V
Tensão suportável nominal de impulso Uimp: 8 kV
Utilisation category AC (IEC 60947-3) : AC-23B (690V/250A)
AC-23A (500V/250A)
AC-22A (690V/250A)

AC20B (800V)
pollution degree 3, visible information required: do not switch under load
Utilisation category DC (IEC 60947-3) : DC-20B (800 V)
pollution degree 3, visible information required: do not switch under load
cond. short-circuit current with fuses (AC): 50 kA / 690V
approved wth fuse links of operation class: gG

Dissipação de energia do artigo:

A dissipação de energia em uma carga de 80% resulta em 52,5 W.

(A dissipação de energia em sua carga máxima seria 82,0 W.)

Dados adicionais IEC

The following values have been verified with tests under certain conditions. Please ask Wöhner for this conditions before designing your panel.

max. permitted operation temperature 55
Special operating conditions corresponding to IEC / EN 61439-1 may yield to foulty activations of pilot switches and fuse monitors. The operating conditions have to be considered for the analysis of status signals.
When several devices are used side-by-side in continuous operation, the rated load factor specified in VDE 0660 Part 500 / EN 60 439-1, Table 1, must be observed.
System component: degree of protection IP20 at front as per DIN EN 60529, degree of protection near terminal depends on installation; shock protection as per DIN EN 50274

adapter module: front side degree of protection IP20 as per DIN EN 60529 (finger-safe)
Dados mecânicos
L x A x P: 184 x 286 x 192
Peso: 555,0 kg/100
Polaridade: 3 polos
para barramentos: 12, 15, 20, 25, 30 x 5, 10 e barramentos de seção

Busbar connector: externally tensioned contacting, convenient click mechanism, simple conversion of the combination bases from 5 to 10mm-thick busbars.

When installing QCS, a busbar support is to be applied left and right, see assembly manual.

pontos terminais
screw connection
M10
screw drive: SW16
Md min.: 30,0 Nm
Md max.: 35,0 Nm
Material properties
halogen-free: No

Instruções de Aplicação

permitted power dissipation of the fuse-link: 23 W
requirements for contact parts: Fuse links with silver-plated contact pieces recommended.
For fuse links with nickel-plated contact pieces, a reduction factor of 0.8 is to be observed.

Links

Downloads

Acessórios

connection accessories

33145 000
terminal prisma, duplo, para cabos de Cu
2x 35 - 70 mm²
para: QCB-NH1, QCS-NH1, QCS-320
Mais

33163 000
conexão tipo grampo para cabos de Cu
70 - 150 mm²
para: QCB-NH2, LTS-F 400, LTS 630
Mais

33166 000
terminal prisma, único, para cabos de Cu
35 - 150 mm²
QCB-NH1, QCS-NH1, QCS-320
para: QCB-NH1, QCS-NH1, QCS-320
Mais

33909 000
prensa-cabo para cabos de Cu
35 - 150 mm²
QCB-NH1, QCS-NH1, QCS-320
para: QCB-NH1, QCS-NH1, QCS-320
Mais

covers

33142 000
cobertura para conector de cabo, fixável na parte superior/inferior
para: QCB-NH1, QCS-NH1, QCS-320
Mais

further accessories

33908 000
interruptor de sinalização para a monitoramento da posição do seccionador
comutador 250 V AC / 5 A, 30 V DC / 4 A
para: QCS-NH00, QCS-NH1, QCS-160, QCS-320
Mais

33910 000
acionamento extraível
preto, com manopla
trava contra porta pode ser ativada, para cadeados
para: QCS-NH00, QCS-NH1, QCS-160, QCS-320
Mais

33911 000
acionamento extraível
amarelo/vermelho, com manopla
trava contra porta pode ser ativada, para cadeados
para: QCS-NH00, QCS-NH1, QCS-160, QCS-320
Mais

33912 000
eixo prolongador, 290 mm de comprimento
para: QCS-NH00, QCS-NH1, QCS-160, QCS-320, CP-PV
Mais

33913 000
eixo prolongador, 490 mm de comprimento
para: QCS-NH00, QCS-NH1, QCS-160, QCS-320, CP-PV
Mais

Encontre sua pessoa de contato

Para a página de contato

Wöhner Sistemas
Eletrotécnicos Ltda.
Rua Antônio Galvão Pacheco, 185
18550-612, Boituva/SPl
Brasil

Linha direta de pedidos (Alemanha)
+49 9563 751 125
order@woehner.de

Linha direta de tecnologia (Alemanha)
+49 9563 751 508
support@woehner.com