Part No.: 31943 000
AMBUS®Panel
holder for cylindrical fuses, with pilot switch
Size 22x58
22 x 58 / 3P
100 A / 690 V
for fuse links with striker pin
for mounting rail
System
Panel
Advantages of the product
large clamping range
| Product group | 17 |
| Subgroup | 12 |
| pack size | 2 |
| EAN | 4021267319434 |
| ECLASS 6.1 | 27142190 |
| ECLASS 7.1 | 27142190 |
| ETIM 4.0 | EC002705 |
| ETIM 5.0 | EC002705 |
Standards
IEC 60947-1:2020
IEC 60947-3:2020 AC ratings only
UL 4248-1
Approvals
CSA , UL , CCC
for UL feeder circuits >250V
type number: AES22x58
UL file: E230163, UL category (for USA): IZLT https://www.ul.com
UL file: E230163, UL category (for Canada): IZLT7 https://www.ul.com
CSA file: 110285, CSA class: 6225-01 https://directories.csa-international.org
CCC certificate: 2012010302584095
| for fuse links size: | 22x58 |
| fuse links acc. to standard: | IEC / HD 60269-2 |
| permitted power dissipation of the fuse-link: | 11 W |
| Details IEC | |
| Standards | |
|
IEC 60947-1:2020 IEC 60947-3:2020 AC ratings only |
| Electrical data IEC | |
| rated current (IEC): | 100 A |
| rated voltage (IEC) AC: | 690 V |
| rated isolation voltage Ui AC: | 800 V |
| rated surge voltage Uimp : | 6 kV |
| cond. short-circuit current with fuses (AC): | 100 kA / 500 V (125 A) |
| 80 kA / 690 V (80 A) | |
| approved wth fuse links of operation class: | gG |
power dissipation of the article:
The power dissipation at a typical load of 80 % results to 6.7 W.
(The power dissipation at full load would be 10.5 W.)
| Supplementary data IEC | |
|
The following values have been verified with tests under certain conditions. Please ask Wöhner for this conditions before designing your panel. |
| further utilisation category AC (IEC 60947-3): | AC-20B (1000 V) at pollution degree 2 |
| A fuse-combination unit acc. to IEC 60947-3 can only be operated at a higher voltage than its rated voltage, if it is used as a fuse-disconnector without breaking capacity, up to its max. rated insulation voltage and labelled as such. |
| for fuse links with striker as per IEC / EN 60269-2 with permitted rated power dissipationsup to max. 9.5W for gG/gL up to max. 7W for aMup to max. 11W for aR/gR at max. 80A pilot switch 1 changeover switch 250V AC (5A), 30V DC (4A) |
| Details UL | |
| Standards | |
| UL 4248-1 |
| for UL feeder circuits >250V | |
| suitable for field-installed conductors |
| Electrical data UL | |
| rated current (UL): | 80 A |
| rated voltage (UL) AC: | 600 V |
| rated frequency (UL): | 50 / 60 Hz |
| rated voltage (UL) DC: | 600 V |
| for wires UL: | Cu 75°C |
| SCCR: | 100 kA |
| Mechanical data | |
| W x H x D: | 108 x 146 x 69 |
| weight: | 54.1 kg/100 |
| poles: | 3-pole |
| Mounting: | for mounting rail |
| degree of protection: | IP20 |
| front degree of protection: | IP20 |
| Terminal points | |
| cage clamp connection | |
| wire stripping: | 20 mm |
| min. cross-section: | 4 mm² |
| max. cross-section: | 50 mm² |
| Md min.: | 3.5 Nm |
| Md max.: | 4.0 Nm |
| Not suitable for aluminium cables ! | |
| min. cross-section UL: | AWG 10 |
| max. cross-section UL: | AWG 1/0 |
| torque (UL): | 35 lb-in |
| for wires UL: | Cu 75°C |
|
box terminal : |
|
| Not suitable for aluminium cables ! | |
| A fuse-combination unit acc. to IEC 60947-3 can only be operated at a higher voltage than its rated voltage, if it is used as a fuse-disconnector without breaking capacity, up to its max. rated insulation voltage and labelled as such. | |
|
Pilot switch indicates if no fuse is inserted, a holder is open or a fuse (with striker) has tripped. |
|
| permitted power dissipation of the fuse-link: | 11 W |
| for UL feeder circuits >250V | |
Find your contact