Código da peça: 31579000B

SECUR®60Classic EasyLiner

seccionador-interruptor-fusível D0 para montagem em barramento 5 polos

para fusíveis D01 e D02, com LED

E18 / 63 A / 3P

operator independent switching (snap-action mechanism)

connection bottom

para barramentos 12, 15, 20, 25, 30 x 5, 10 e barramentos de seção

Sistema

60Classic

Vantagens do produto

spring terminal enables connection without tools (at first installation)

Grupo de produto 01
Subgroup 42
Unidade por pacote 1
EAN 4021267315795
ECLASS 6.1 27142110
ECLASS 7.1 27142110
ETIM 4.0 EC000277
ETIM 5.0 EC000277

Aprovações

Standards

IEC 60947-1:2020
IEC 60947-3:2020 AC ratings only

Approvals

IEC (CB) , VDE , CCC

Número de tipo: SEL

CCC certificate: 2014010302710123

Dados técnicos

for fuse links size: D0
fuse links acc. to standard: IEC / HD 60269-3
permitted power dissipation of the fuse-link: 5,5 W
requirements for contact parts: use fuse links with silver-plated contacts
Dados IEC
Standards
IEC 60947-1:2020
IEC 60947-3:2020 AC ratings only
Dados elétricos IEC
Corrente de medição (IEC): 63 A
Tensão de medição (IEC) AC: 400 V
rated frequency (IEC): 50 / 60 Hz
Tensão nominal de isolamento: 500 V
Tensão suportável nominal de impulso Uimp: 6 kV
Utilisation category AC (IEC 60947-3) : AC-22B (400 V)
cond. short-circuit current with fuses (AC): 50 kA / 400 V
approved wth fuse links of operation class: gG

Dissipação de energia do artigo:

A dissipação de energia em uma carga de 80% resulta em 4,5 W.

(A dissipação de energia em sua carga máxima seria 7,0 W.)

Dados adicionais IEC

The following values have been verified with tests under certain conditions. Please ask Wöhner for this conditions before designing your panel.

A fuse-combination unit acc. to IEC 60947-3 can only be operated at a higher voltage than its rated voltage, if it is used as a fuse-disconnector without breaking capacity, up to its max. rated insulation voltage and labelled as such.
reduction factor at ambient temperature:
35°C     1,0
45°C     0,9
55°C     0,8
for fuse links and gauge elements acc. to IEC / HD 60269-3

use of D02 fuse links with silver plated caps is recommended

The function of isolation between incoming and outgoing contacts is provided by the opening of the switching mechanism as required in the standard.

There is a transfer of the potential from the busbars, through the LED units, to the terminals  when the fuse links are removed and the switching mechanismn is closed.

Dados mecânicos
L x A x P: 27 x 200 x 80
Peso: 33,0 kg/100
Polaridade: 3 polos
para barramentos: 12, 15, 20, 25, 30 x 5, 10 e barramentos de seção
front degree of protection: IP20
pontos terminais
spring pulley connection
screw drive: PZ2
wire stripping: 12 mm
min. cross-section: 1,5 mm²
max. cross-section: 16 mm²
Md min.: 2,5 Nm
Md max.: 3,0 Nm
Not suitable for aluminium cables !
  

1,5 - 16 mm² round stranded and flexible without wire-end ferrule
1,5 - 16 mm²  flexible with wire-end ferrule*
1,5 - 10 mm²  flexible with wire-end ferrule
1,5 - 10 mm² round solid

* 16 mm² prepared with crimping tool PZ 16 (Weidmüller) or
with jointing clamp Crimpfox 25R (Phoenix Contact)

the connecting wires can be placed at the side :
up to 6mm² without side module
up to 10mm² when using  the side module

Instruções de Aplicação

Not suitable for aluminium cables !
A fuse-combination unit acc. to IEC 60947-3 can only be operated at a higher voltage than its rated voltage, if it is used as a fuse-disconnector without breaking capacity, up to its max. rated insulation voltage and labelled as such.

Notas

The devices have to be equipped with D0 gauge rings. Together with reducer part no. 31902 also suitable for fuse-links D01.
The use of the side module part no. 31914 is recommended for continuous loads of 35 A or greater.

can not be used in 5-pole busbar systems 250 A and 400 A of company Hensel.

use of D02 fuse-links with silver plated caps is required

LED lights when the fuse-link trips or is missing

can be locked (padlock) in OFF position (O) and sealed in ON position (1)

permitted power dissipation of the fuse-link: 5,5 W
requirements for contact parts: use fuse links with silver-plated contacts

Links

Downloads

Acessórios

31902000
redutor D02 para fusíveis D01 2 - 16 A
Mais

31915000A
módulo lateral de 9 mm para 31578 e 31579
Mais

31976000A
interruptor de sinalização
comutador 250 250 V AC / 5 A, 30 V DC / 4 A
Mais

Similar products

31575000B
SECUR®60Classic EasyLiner
seccionador-interruptor-fusível D0 em barramento 3 polos
para fusíveis D01 e D02, com LED
E18 / 63 A / 3P
connection bottom
para barramentos: 12, 15, 20, 25, 30 x 5, 10 e barramentos de seção
Mais

31578000B
SECUR®60Classic EasyLiner
seccionador-interruptor-fusível D0 em barramento 5 polos
para fusíveis D01 e D02
E18 / 63 A / 3P
connection bottom
para barramentos: 12, 15, 20, 25, 30 x 5, 10 e barramentos de seção
Mais

31574000B
SECUR®60Classic EasyLiner
seccionador-interruptor-fusível D0 em barramento 3 polos
para fusíveis D01 e D02
E18 / 63 A / 3P
connection bottom
para barramentos: 12, 15, 20, 25, 30 x 5, 10 e barramentos de seção
Mais

31588000A
SECUR®60Classic EasyLiner
seccionador-interruptor-fusível D0 em barramento 5 polos
Para fusíveis D01 e D02, para sistemas de barramento 250 A, 400 A e 630 A da empresa Hensel
E18 / 63 A / 3P
connection bottom
para barramentos: 12, 20, 30 x 5, 10
Mais

Encontre sua pessoa de contato

Para a página de contato

Wöhner Sistemas
Eletrotécnicos Ltda.
Rua Antônio Galvão Pacheco, 185
18550-612, Boituva/SPl
Brasil

Linha direta de pedidos (Alemanha)
+49 9563 751 125
order@woehner.de

Linha direta de tecnologia (Alemanha)
+49 9563 751 508
support@woehner.com