Seleção de produtos

for UL feeder circuits >250V

suporte para fusíveis cilíndricos, com LED (31924)

A imagem pode mostrar um produto similar.

Descrição

Código da peça: 31924000

AMBUS®Panel

suporte para fusíveis cilíndricos, com LED

Class J / 2P, prensa-cabo 50 mm²

60 A / 600 V (27x60)

für DIN Tragschiene

Sistema

DIN rail

Vantagens do produto

large clamping range, also for two identical conductors (adjacent)
holder for label
with indicator for tripped fuse
any polarity for DC voltage applications

Grupo de produto 16
Subgroup 06
UE 3
EAN 4021267319243
catalog page 2020 : 6.10
ECLASS 6.1 27142190
ECLASS 7.1 27142190
ETIM 4.0 EC002705
ETIM 5.0 EC002705

Aprovações

Standards

IEC 60269-1:2006 + A1:2009 + A2:2014
IEC 60269-2:2013 + A1:2016, Fuse system H

UL 4248-8

UL 4248-1

Approvals

CSA , UL , EAC

for UL feeder circuits >250V

Número de tipo: AJC60

EAC Type: AJC

UL file: E230163, UL category (for USA): IZLT https://www.ul.com

UL file: E230163, UL category (for Canada): IZLT7 https://www.ul.com

CSA file: 110285, CSA class: 6225-01 https://directories.csa-international.org

Dados técnicos

for fuse links size: Class J 60 A
fuse links acc. to standard: UL 248-8
permitted power dissipation of the fuse-link: 7 W
Dados IEC
Standards
IEC 60269-1:2006 + A1:2009 + A2:2014
IEC 60269-2:2013 + A1:2016, Fuse system H
Dados elétricos IEC
min. operating voltage AC: 110 V
min. operating voltage DC: 110 V

Dissipação de energia do artigo:

A dissipação de energia em uma carga de 80% resulta em 1,7 W.

(A dissipação de energia em sua carga máxima seria 2,6 W.)

for Class J fuses 35 - 60A as per UL 248-8 (27x60)

indicator light
operating voltage range: 110 - 600 V AC / DC
Dados UL
Standards
UL 4248-8
UL 4248-1
for UL feeder circuits >250V
suitable for field-installed conductors
Dados electricos UL
rated current (UL): 60 A
rated voltage (UL) AC: 600 V
min. operating voltage AC: 110 V
rated frequency (UL): 50 / 60 Hz
rated voltage (UL) DC: 600 V
min. operating voltage DC: 110 V
for wires UL: Cu 75°C
SCCR: 200 kA
Dados mecânicos
L x A x P: 80 x 118 x 82
Peso: 37,0 kg/100
Polaridade: 2 polos
Mounting: für DIN Tragschiene
degree of protection: IP20
front degree of protection: IP20
pontos terminais
Not suitable for aluminium cables !
  
min. cross-section UL: AWG 14
max. cross-section UL: AWG 1/0
for wires UL: Cu 75°C
  

for applications acc. to IEC / EN :
1 wire : Cu 6 - 50 mm², Md 3,5 - 4,0 Nm / 31 - 35 lb.in.
2 wires (of same cross-section) : Cu 6 - 16 mm², Md 3,5 - 4,0 Nm / 31 - 35 lb.in.
flexible cables, directly or with wire-end ferrule
(flexible cables of max. cross-section may not fit when using wire-end ferrule)

for applications acc. to UL / CSA :
only Cu cables acc. to UL 486E
1 wire : AWG 14 - AWG 1, Class C, Md 4,0 Nm / 35 lb.in.
2 wires (of identical cross-section) :  AWG 14 - AWG 6, Class C, Md 4,0 Nm / 35 lb.in.

Links

Downloads

Acessórios

31360000
fusível 35 A
-Mersen-
600 V AC, time delay
Class J, 27x60
Mais

31361000
fusível 40 A
-Mersen-
600 V AC, time delay
Class J, 27x60
Mais

31362000
fusível 45 A
-Mersen-
600 V AC, time delay
Class J, 27x60
Mais

31363000
fusível 50 A
-Mersen-
600 V AC, time delay
Class J, 27x60
Mais

31364000
fusível 60 A
-Mersen-
600 V AC, time delay
Class J, 27x60
Mais

31511000A
fusível 35 A
-Mersen-
600 V AC, fast acting
Class J, 27x60
Mais

31512000A
fusível 40 A
-Mersen-
600 V AC, fast acting
Class J, 27x60
Mais

31514000A
fusível 50 A
-Mersen-
600 V AC, fast acting
Class J, 27x60
Mais

31515000A
fusível 60 A
-Mersen-
600 V AC, fast acting
Class J, 27x60
Mais

Similar products

31920000
AMBUS®Panel
suporte para fusíveis cilíndricos
Class J / 1P, prensa-cabo 50 mm²
60 A / 600 V (27x60)
Mais

Encontre sua pessoa de contato

Para a página de contato

Wöhner Sistemas
Eletrotécnicos Ltda.
Rua Antônio Galvão Pacheco, 185
18550-612, Boituva/SPl
Brasil

Linha direta de pedidos (Alemanha)
+49 9563 751 125
order@woehner.de

Linha direta de tecnologia (Alemanha)
+49 9563 751 508
support@woehner.com

Produtos Configurador Current metal surcharges folder for files