Selezione prodotto

for UL feeder circuits >250V

Base sezion. per fusibili cilindr., con LED (31924)

The picture may show a similar product.

Descrizione

Cod.art.: 31924000

AMBUS®Panel

Base sezion. per fusibili cilindr., con LED

Class J / 2P, morsetti 50 mm²

60 A / 600 V (27x60)

für DIN Tragschiene

Montaggio

DIN rail

Vantaggi prodotto

large clamping range, also for two identical conductors (adjacent)
holder for label
with indicator for tripped fuse
any polarity for DC voltage applications

gruppo di prodotto 16
sottogruppo prodotto 06
pz/ conf. 3
EAN 4021267319243
pagina catalogo 2020 : 6.10
ECLASS 6.1 27142190
ECLASS 7.1 27142190
ETIM 4.0 EC002705
ETIM 5.0 EC002705

Certificazioni

Norme

IEC 60269-1:2006 + A1:2009 + A2:2014
IEC 60269-2:2013 + A1:2016, Fuse system H

UL 4248-8

UL 4248-1

Omologazioni

CSA , UL , EAC

for UL feeder circuits >250V

type no.: AJC60

EAC Type: AJC

UL file: E230163, UL category (for USA): IZLT https://www.ul.com

UL file: E230163, UL category (for Canada): IZLT7 https://www.ul.com

CSA file: 110285, CSA class: 6225-01 https://directories.csa-international.org

Dati tecnici

per fusibili di grandezza: Class J 60 A
fusibile secondo norma: UL 248-8
potenza diss. max. ammissibile del fusibile inserito: 7 W
Details IEC
Norme
IEC 60269-1:2006 + A1:2009 + A2:2014
IEC 60269-2:2013 + A1:2016, Fuse system H
Electrical data IEC
tensione min. di impiego AC: 110 V
tensione min. di impiego DC: 110 V

power dissipation of the article:

The power dissipation at a typical load of 80 % results to 1,7 W.

(The power dissipation at full load would be 2,6 W.)

for Class J fuses 35 - 60A as per UL 248-8 (27x60)

indicator light
operating voltage range: 110 - 600 V AC / DC
Details UL
Norme
UL 4248-8
UL 4248-1
for UL feeder circuits >250V
suitable for field-installed conductors
Electrical data UL
corrente nominale (UL): 60 A
tensione nominale (UL) AC: 600 V
tensione min. di impiego AC: 110 V
frequenza nominale (UL): 50 / 60 Hz
tensione nominale (UL) DC: 600 V
tensione min. di impiego DC: 110 V
for wires UL: Cu 75°C
SCCR: 200 kA
Valori meccanici
L x A x P: 80 x 118 x 82
peso: 37,0 kg/100
Poli: 2 poli
Mounting: für DIN Tragschiene
grado di protezione: IP20
grado di protezione dal fronte: IP20
Connessioni
Not suitable for aluminium cables !
  
min. cross-section UL: AWG 14
max. cross-section UL: AWG 1/0
for wires UL: Cu 75°C
  

for applications acc. to IEC / EN :
1 wire : Cu 6 - 50 mm², Md 3,5 - 4,0 Nm / 31 - 35 lb.in.
2 wires (of same cross-section) : Cu 6 - 16 mm², Md 3,5 - 4,0 Nm / 31 - 35 lb.in.
flexible cables, directly or with wire-end ferrule
(flexible cables of max. cross-section may not fit when using wire-end ferrule)

for applications acc. to UL / CSA :
only Cu cables acc. to UL 486E
1 wire : AWG 14 - AWG 1, Class C, Md 4,0 Nm / 35 lb.in.
2 wires (of identical cross-section) :  AWG 14 - AWG 6, Class C, Md 4,0 Nm / 35 lb.in.

Links

Downloads

Accessori

31360000
Fusibile 35 A
-Mersen-
600 V AC, time delay
Class J, 27x60
Di Più

31361000
Fusibile 40 A
-Mersen-
600 V AC, time delay
Class J, 27x60
Di Più

31362000
Fusibile 45 A
-Mersen-
600 V AC, time delay
Class J, 27x60
Di Più

31363000
Fusibile 50 A
-Mersen-
600 V AC, time delay
Class J, 27x60
Di Più

31364000
Fusibile 60 A
-Mersen-
600 V AC, time delay
Class J, 27x60
Di Più

31511000A
Fusibile 35 A
-Mersen-
600 V AC, fast acting
Class J, 27x60
Di Più

31512000A
Fusibile 40 A
-Mersen-
600 V AC, fast acting
Class J, 27x60
Di Più

31514000A
Fusibile 50 A
-Mersen-
600 V AC, fast acting
Class J, 27x60
Di Più

31515000A
Fusibile 60 A
-Mersen-
600 V AC, fast acting
Class J, 27x60
Di Più

Similar products

31920000
AMBUS®Panel
Base sezion. per fusibili cilindr.
Class J / 1P, morsetti 50 mm²
60 A / 600 V (27x60)
Di Più

Trova il tuo contatto

to the contact site

Wöhner GmbH & Co. KG
Elektrotechnische Systeme
Mönchrödener Str. 10
96472 Rödental

Order hotline (Germany)
+49 9563 751 161
order@woehner.de

Technical hotline (Germany)
+49 9563 751 260
support@woehner.com

Prodotti Configuratore Addizionali metalli folder for files