Inovações
Produtos
A imagem pode mostrar um produto similar.
Código da peça: 33771000A
QUADRON®185Power
chave seccionadora de fusível vertical 160 A
Tamanho 00, comutável 3 polos, com monitorização do fusível
high version with box terminal 70 mm²
para barramentos 30, 40, 60, 80, 100, 120 x 10
Sistema
185Power
Vantagens do produto
Self-closing inspection holes are available in the cover.
Cover can be locked when closed.
Grupo de produto | 12 |
Subgroup | 52 |
Unidade por pacote | 1 |
EAN | 4021267337711 |
ECLASS 6.1 | 27142108 |
ECLASS 7.1 | 27142108 |
ETIM 4.0 | EC001046 |
ETIM 5.0 | EC001046 |
Standards
IEC 60947-1:2020
IEC 60947-3:2020 AC ratings only
Approvals
IEC (CB) , CCC
Número de tipo: QU185-00
CCC certificate: 2015010302769751
for fuse links size: | NH 000, NH 00 |
fuse links acc. to standard: | IEC / HD 60269-2 |
permitted power dissipation of the fuse-link: | 12 W |
requirements for contact parts: |
Fuse links with silver-plated contact pieces recommended. For fuse links with nickel-plated contact pieces, a reduction factor of 0.8 is to be observed. |
Dados IEC | |
Standards | |
IEC 60947-1:2020 IEC 60947-3:2020 AC ratings only |
Dados elétricos IEC | |
Corrente de medição (IEC): | 160 A |
Tensão de medição (IEC) AC: | 400 V |
Tensão nominal de isolamento: | 400 V |
Tensão suportável nominal de impulso Uimp: | 4 kV |
Utilisation category AC (IEC 60947-3) : | AC-23B 160A/400V |
cond. short-circuit current with fuses (AC): | 100 kA / 400 V |
approved wth fuse links of operation class: | gG |
Dissipação de energia do artigo:
A dissipação de energia em uma carga de 80% resulta em 17,9 W.
(A dissipação de energia em sua carga máxima seria 28,0 W.)
Dados adicionais IEC | |
The following values have been verified with tests under certain conditions. Please ask Wöhner for this conditions before designing your panel. |
A fuse-combination unit acc. to IEC 60947-3 can only be operated at a higher voltage than its rated voltage, if it is used as a fuse-disconnector without breaking capacity, up to its max. rated insulation voltage and labelled as such. |
Special operating conditions corresponding to IEC / EN 61439-1 may yield to foulty activations of pilot switches and fuse monitors. The operating conditions have to be considered for the analysis of status signals. | |
Degree of protection IP20 at front, degree of protection near terminal depends on installation |
Dados mecânicos | |
L x A x P: | 50 x 670 x 189 |
Peso: | 270,0 kg/100 |
para barramentos: | 30, 40, 60, 80, 100, 120 x 10 |
front degree of protection: | IP20 |
Type of fastening:
can be screwed onto drilled busbar, undrilled mounting with terminal clamp
connection:
box terminal 95mm²
pontos terminais | |
Box terminal: |
A fuse-combination unit acc. to IEC 60947-3 can only be operated at a higher voltage than its rated voltage, if it is used as a fuse-disconnector without breaking capacity, up to its max. rated insulation voltage and labelled as such. | |
Notas |
Verwendete Variante der Sicherungsüberwachung: IL9075.12/010 |
permitted power dissipation of the fuse-link: | 12 W |
requirements for contact parts: |
Fuse links with silver-plated contact pieces recommended. For fuse links with nickel-plated contact pieces, a reduction factor of 0.8 is to be observed. |
Encontre sua pessoa de contato
Para a página de contato
Wöhner Sistemas
Eletrotécnicos Ltda.
Rua Antônio Galvão Pacheco, 185
18550-612, Boituva/SPl
Brasil
Linha direta de pedidos (Alemanha)
+49 9563 751 125
order@woehner.de
Linha direta de tecnologia (Alemanha)
+49 9563 751 508
support@woehner.com