busbar adapter 63 A (32461)

The picture may show a similar product.

Description

Part No.: 32461000

EQUES®60Classic

busbar adapter 63 A

2 adjustable mounting rails

54 x 260, with leads AWG 8 (10 mm²)

for busbars 12, 15, 20, 25, 30 x 5, 10 and section busbars

System

60Classic

Advantages of the product

Conductor ends ultrasonically sealed.
Click mechanism when pushing onto the busbar.

Product group 05
Subgroup 24
pack size 4
EAN 4021267324612
ECLASS 6.1 27370304
ECLASS 7.1 27370304
ETIM 4.0 EC001531
ETIM 5.0 EC001531

Approvals

Standards

IEC 61439-1:2020

UL 508

Approvals

CSA , UL , DNV GL

for UL feeder circuits >250V

type number: EEC6063-L

UL file: E123577, UL category (for USA): NMTR https://www.ul.com

UL file: E123577, UL category (for Canada): NMTR7 https://www.ul.com

CSA file: 110285, CSA class: 3211-37 https://directories.csa-international.org

CCC approval: no certification required

Technical data

Details IEC
Standards
IEC 61439-1:2020
Electrical data IEC
rated current (IEC): 63 A
rated voltage (IEC) AC: 690 V
rated isolation voltage Ui AC: 800 V
rated surge voltage Uimp : 6 kV

power dissipation of the article:

The power dissipation at a typical load of 80 % results to 4,4 W.

(The power dissipation at full load would be 6,9 W.)

Details UL
Standards
UL 508
for UL feeder circuits >250V
Electrical data UL
rated current (UL): 65 A
rated voltage (UL) AC: 600 V
rated frequency (UL): 50 / 60 Hz
SCCR unprotected max.: 7,5 kA
3 cycles (without OPD) @ 600 V AC
SCCR protected max.: 100 kA
SCCR: 100 kA with MS45x 60 A / 480 V AC
100 kA with PKZ5 60 A / 480 V AC
Mechanical data
W x H x D: 54 x 260 x 63
weight: 43,0 kg/100
poles: 3-pole
for busbars: 12, 15, 20, 25, 30 x 5, 10 and section busbars

Application notes

There must be a clearance of at least 12 mm above the article to remove it from the busbar system.

Reference

For compact mounting of complete motor circuits with commercially available switchgear and safe mechanical and electrical connection to the busbar system.

short-circuit withstandability: the short-circuit capacity of the combination of adapter and motor starter depends on the motor starter
for UL feeder circuits >250V

Links

Downloads

Accessories

32948000
mounting rail 54 mm
for busbar adapters
More

32969000
mounting rail end stop
More

32963000
side-mounted module for busbar adapters
attachable to both sides
9 x 200
for: EEC60..
More

32953000A
positioning piece for Siemens S2
NEW
More

Find your contact

to the contact site

Wöhner GmbH & Co. KG
Elektrotechnische Systeme
Mönchrödener Str. 10
96472 Rödental

Order hotline (Germany)
+49 9563 751 161
order@woehner.de