basic system 250 A (11400000A)

The picture may show a similar product.

Description

Part No.: 11400 000A

CrossBoard

basic system 250 A

3-pole

400 mm long, touch-safe protected

with CrossLink interface

System

CrossBoard 125A / 250A

Advantages of the product

touch-safe protected busbar system up to 250 A
rear feedable
plug and play
easy to screw to mounting plates
completely pre-assembled and immediately ready for use

Product group 06
Subgroup 50
pack size 1
EAN 4021267114008
ECLASS 14.0 27400613
ETIM 5.0 EC001900
ETIM 8.0 EC001900
ETIM 10.0 EC001900

Approvals

Standards

IEC 61439-1:2020

UL 508

Approvals

IEC (CB) , UL

for UL feeder circuits >250V

type number: CB-XL-400-24x16

EAC Type: CB

UL file: E123577, UL category (for USA): NMTR https://www.ul.com

UL file: E123577, UL category (for Canada): NMTR7 https://www.ul.com

CCC approval: no certification required

Technical data

Details IEC
Standards
IEC 61439-1:2020
Electrical data IEC
rated current (IEC): 250 A
rated voltage (IEC) AC: 690 V
rated isolation voltage Ui AC: 800 V
rated surge voltage Uimp : 6 kV
rated peak withstand current  Ipk max.: 30 kA
rated short-time withstand current Icw (0.1 s) max.: 15 kA

power dissipation of the article:

The power dissipation at a typical load of 80 % results to 12,5 W.

(The power dissipation at full load would be 19,5 W.)

Supplementary data IEC

The following values have been verified with tests under certain conditions. Please ask Wöhner for this conditions before designing your panel.

max. permitted voltage (IEC) DC: 800 V
min. permitted operation temperature -40°C
Details UL
Standards
UL 508
for UL feeder circuits >250V
Electrical data UL
rated current (UL): 250 A
rated voltage (UL) AC: 600 V
rated frequency (UL): 50 / 60 Hz
rated voltage (UL) DC: 600 V
SCCR unprotected max.: 10 kA
3 cycles (without OPD) @ 600 V AC
SCCR protected max.: 100 kA
with JDDZ fuse Class J 400 A / 600 V AC
SCCR: 100 kA with JDDZ fuse Class J 400 A / 600 V AC
65 kA with any DIVQ/7 circuit breaker 400 A / 480 V AC
Mechanical data
W x H x D: 400 x 160 x 45
weight: 159,7 kg/100
poles: 3-pole
degree of protection: IP20
Material properties
Material: Copper
Ausführung Werkstoff: unbehandelt
halogen-free: Yes

Application notes

Crossboards before production date November 2024 also suitable for 250 A (IEC + UL). Confirmation

for UL feeder circuits >250V

Links (Prices, CAD data)

Downloads

Find your contact

to the contact site

Wöhner GmbH & Co. KG
Elektrotechnische Systeme
Mönchrödener Str. 10
96472 Rödental

Order hotline (Germany)
+49 9563 751 161
order@woehner.de

Technical hotline (Germany)
+49 9563 751 260
support@woehner.com