Part No.: 36127 000A

MOTUS®30Compact

hybrid motor starter, 3-pole

direct and reversing starter 1.5 - 7.0 A / switch for resistive loads 1.5 - 9.0 A

with IO-Link interface

for busbars 12 x 5, 10

with CrossLink®Technology

phase-out product

Auslaufdatum: 31.03.2026

System

30Compact 3P

Advantages of the product

4 functions integrated:
Right contactor
Left contactor
Motor protection relay

Installed width only 22.5mm
30 million electrical switching operations

Product group 21
Subgroup 06
pack size 1
EAN 4021267361273
ETIM 5.0 EC001037
ETIM 8.0 EC001037

Approvals

Standards

IEC 60947-1:2007 + A1:2010 + A2:2014
IEC 60947-4-2:2011
IEC 61508-1:2010
ISO 13849-1:2015

UL 60947-1

Approvals

UL

for UL feeder circuits >250V

type number: 36131

UL file: E360470, UL category (for USA): NLDX https://www.ul.com

UL file: E360470, UL category (for Canada): NLDX7 https://www.ul.com

Technical data

Details IEC
Standards
IEC 60947-1:2007 + A1:2010 + A2:2014
IEC 60947-4-2:2011
IEC 61508-1:2010
ISO 13849-1:2015
Electrical data IEC
rated current (IEC): 9 A
rated voltage (IEC) AC: 500 V
min. operating voltage AC: 42 V
trigger characteristic: Class 10A
set nominal current: Yes
min. load current: 1.5 A
max. switching frequency: 2 Hz
switching cycles: 30.000.000
rated frequency (IEC): 50 / 60 Hz
rated isolation voltage Ui AC: 550 V
rated surge voltage Uimp : 6 kV

power dissipation of the article:

The power dissipation at a typical load of 80 % results to 7,7 W.

(The power dissipation at full load would be 12,0 W.)

Supplementary data IEC

The following values have been verified with tests under certain conditions. Please ask Wöhner for this conditions before designing your panel.

min. permitted operation temperature -25
max. permitted operation temperature 70
min. permitted temperature for transport and storage -40
max. permitted temperature for transport and storage 80
Details UL
Standards
UL 60947-1
for UL feeder circuits >250V
Electrical data UL
rated current (UL): 7.6 A
rated voltage (UL) AC: 500 V
min. operating voltage AC: 42 V
rated frequency (UL): 50 / 60 Hz
SCCR unprotected max.: 5 kA
3 cycles (without OPD) @ 600 V AC
SCCR protected max.: 100 kA
SCCR: 100 kA with JDDZ fuse Class J 175 A / 600 V AC
Mechanical data
W x H x D: 22.5 x 160 x 114.5
weight: 55,9 kg/100
poles: 3-pole
for busbars: 12 x 5, 10
degree of protection: IP20
vertical installation position: Yes
horizontal installation position: No
Terminal points
screw clamp connection
screw drive: 0,8x4
wire stripping: 8 mm
min. cross-section: 0,2 mm²
max. cross-section: 2,5 mm²
Md min.: 0,5 Nm
Md max.: 0,6 Nm
  
min. cross-section UL: AWG 24
max. cross-section UL: AWG14
torque (UL): 5,0 - 7,0 lb-in
  

Screw terminals (solid round, flexible, flexible with wire-end ferrule)
0.14 - 2.5mm² / 0.5 - 0.6Nm
The cable outlet is provided with a pluggable terminal

Material properties
halogen-free: Yes

Application notes

permitted degree of polution: 2
for UL feeder circuits >250V

Links

Downloads

Accessories

spare parts

31568 000
replacement fuse for MOTUS®
Size 10x38
fuse 20 A for version 9 A
10x38 gR
More

31569 000
replacement fuse for MOTUS®
Size Class CC
fuse 30 A for version 9 A for motors with heavy-duty starting
Class CC
More

Similar products

36101 000B
MOTUS®30Compact
hybrid motor starter, 3-pole
direct and reversing starter 0.075 - 0.6 A / switch for resistive loads 0.075 - 0.6 A
for busbars: 12 x 5, 10
More

36104 000B
MOTUS®30Compact
hybrid motor starter, 3-pole
direct and reversing starter 0.18 - 2.4 A / switch for resistive loads 0.18 - 2.4 A
for busbars: 12 x 5, 10
More

Find your contact

to the contact site

Wöhner GmbH & Co. KG
Elektrotechnische Systeme
Mönchrödener Str. 10
96472 Rödental

Order hotline (Germany)
+49 9563 751 161
order@woehner.de

Technical hotline (Germany)
+49 9563 751 260
support@woehner.com