Innovationen
产品
The picture may show a similar product.
订货号 31281000
AMBUS®Panel
熔断器式隔离器
22 x 58 / 1P
100 A / 690 V
for mounting rail
系统
Panel
产品优势
连接夹开口空间较大
产品组 | 17 |
分组 |
12 |
包装件数 | 6 |
EAN | 4021267312817 |
ECLASS 6.1 | 27142190 |
ECLASS 7.1 | 27142190 |
ETIM 4.0 | EC002705 |
ETIM 5.0 | EC002705 |
标准
IEC 60947-1:2020
IEC 60947-3:2020 AC ratings only
UL 4248-1
认证许可
IEC (CB) , CSA , UL , CCC
for UL feeder circuits >250V
型号: AES22x58
UL 文件: E230163, UL 类别 (适用美国) : IZLT https://www.ul.com
UL 文件: E230163, UL 类别 (适用加拿大) : IZLT7 https://www.ul.com
CSA 文件: 110285, CSA 等级: 6225-01 https://directories.csa-international.org
CCC认证: 2012010302584095
for fuse links size: | 22x58 |
fuse links acc. to standard: | IEC / HD 60269-2 |
所使用熔断器的允许损耗功率: | 11 W |
Details IEC | |
标准 | |
IEC 60947-1:2020 IEC 60947-3:2020 AC ratings only |
Electrical data IEC | |
额定电流(IEC): | 100 A |
额定电压(IEC)AC: | 690 V |
rated isolation voltage Ui AC: | 800 V |
额定绝缘电压 Ui DC: | 800 V |
额定冲击耐受电压 Uimp: | 6 kV |
带熔断器时的条件额定短路电流: | 100 kA / 500 V (125 A) |
80 kA / 690 V (80 A) | |
带熔断器测定的工作等级: | gG |
功率输出:
The power dissipation at a typical load of 80 % results to 2.2 W.
(The power dissipation at full load would be 3.5 W.)
Supplementary data IEC | |
下述参数已经在特定条件下通过测试得到验证。开始设计之前,请联系维纳尔咨询这些条件。 |
further utilisation category AC (IEC 60947-3): | AC-20B (1000 V) at pollution degree 2 |
further utilisation category DC (IEC 60947-3): | DC-20B (800 V) |
符合 IEC 60947-3 的熔断器组合电器,只有在作为没有分断能力的熔断器式隔离器时、在不超过额定绝缘电压使用并进行相应的标识时,才允许超过额定工作电压运行。 |
适用于熔断器 符合IEC / EN 60269-2 具有允许的额定损耗功率: gG/gL 最大9.5W; aM最大7W, 在额定工作条件下aR / gR / gRL最大11W, 此时必须连接横截面积最少50 mm²的导线 |
Details UL | |
标准 | |
UL 4248-1 |
for UL feeder circuits >250V | |
suitable for field-installed conductors |
Electrical data UL | |
额定电流 (UL): | 80 A |
额定电压 (UL) AC: | 600 V |
rated frequency (UL): | 50 / 60 Hz |
额定电压 (UL) DC: | 600 V |
for wires UL: | Cu 75°C |
SCCR: | 100 kA |
机械数值 | |
宽 x 高 x 厚: | 36 x 115 x 69 |
重量: | 15.8 kg/100 |
极数: | 1线 |
Mounting: | for mounting rail |
防护等级: | IP20 |
正面防护等级: | IP20 |
连接端 | |
cage clamp connection | |
wire stripping: | 20 mm |
min. cross-section: | 4 mm² |
最大横截面积: | 50 mm² |
Md min.: | 3.5 Nm |
Md max.: | 4.0 Nm |
Not suitable for aluminium cables ! | |
最小横截面积: | AWG 10 |
max. cross-section UL: | AWG 1/0 |
torque (UL): | 35 lb-in |
for wires UL: | Cu 75°C |
框端子 : |
Not suitable for aluminium cables ! | |
符合 IEC 60947-3 的熔断器组合电器,只有在作为没有分断能力的熔断器式隔离器时、在不超过额定绝缘电压使用并进行相应的标识时,才允许超过额定工作电压运行。 | |
所使用熔断器的允许损耗功率: | 11 W |
for UL feeder circuits >250V |
获取联系人
跳转至联系页面
电话:+86 10 67870300
邮箱:info@woehner.com.cn
网站:woehner.com.cn