terminal de pinças (01135)

A imagem pode mostrar um produto similar.

Descrição

Código da peça: 01135000

CRITO®

terminal de pinças

35 - 150 mm², AWG 2 - 300 MCM,  lam. Cu. 15 - 20 x 5 - 10

para barramentos 12, 15, 20 x 5, 10

Sistema

60Classic, 30Compact 3P

Vantagens do produto

Terminal with captive clamping screws, conductor can be overlapped.
Indication of nominal cross-section and tightening torque noted on the terminal.
Contact between conductor and busbar via cable bed.

Grupo de produto 07
Subgroup 19
Unidade por pacote 6
EAN 4021267011352
ECLASS 6.1 27141146
ECLASS 7.1 27141146
ETIM 4.0 EC000001
ETIM 5.0 EC000001

Aprovações

Standards

IEC 61439-1:2020
IEC 60999-1:1999
IEC 60999-2:2003

UL 508

Approvals

UL

for UL feeder circuits >250V

Número de tipo: 515-L

UL file: E123577, UL category (for USA): NMTR https://www.ul.com

UL file: E123577, UL category (for Canada): NMTR7 https://www.ul.com

Aprovação CCC: no certification required

Dados técnicos

Dados IEC
Standards
IEC 61439-1:2020
IEC 60999-1:1999
IEC 60999-2:2003
Dados elétricos IEC
Corrente de medição (IEC): 275 A
Tensão de medição (IEC) AC: 690 V
rated peak withstand current  Ipk max.: 49.8 kA
Dados adicionais IEC

The following values have been verified with tests under certain conditions. Please ask Wöhner for this conditions before designing your panel.

tensão máxima IEC AC: 1000 V
tensão máxima IEC DC: 1500 V
current capacity (IEC) max.: 480 A
Dados UL
Standards
UL 508
for UL feeder circuits >250V
suitable for field-installed conductors
Dados electricos UL
corrente nominal (UL): 285 A
rated voltage (UL) AC: 600 V
rated frequency (UL): 50 / 60 Hz
SCCR: 18 kA
Dados mecânicos
L x A x P: 28 x 34 x 69
Peso: 10,2 kg/100
para barramentos: 12, 15, 20 x 5, 10
pontos terminais
min. cross-section: 35 mm²
max. cross-section: 150 mm²
Área de aperto: 20 x 22
Suitable for aluminium cables.
When using aluminium cables, observe the maintenance instructions.
  

for applications acc. to IEC / EN :
Cu or Al 35 - 150 mm² stranded round cables and stranded sectored cables
Cu also flexible cables, directly or with wire-end ferrule
(flexible cables of maximum cross-section may not fit when using wire-end ferrule)

for applications acc. to UL / CSA :
Cu 35 - 150 mm² / AWG 2 - MCM 300

Instruções de Aplicação

Suitable for aluminium cables.
When using aluminium cables, observe the maintenance instructions.
The insulation performance of the article depends on the installation conditions.
for UL feeder circuits >250V

Links

Downloads

Encontre sua pessoa de contato

Para a página de contato

Wöhner Sistemas
Eletrotécnicos Ltda.
Rua Antônio Galvão Pacheco, 185
18550-612, Boituva/SPl
Brasil

Linha direta de pedidos (Alemanha)
+49 9563 751 125
order@woehner.de

Linha direta de tecnologia (Alemanha)
+49 9563 751 508
support@woehner.com