Seleção de produtos

for UL feeder circuits >250V

módulo de conexão (01594)

A imagem pode mostrar um produto similar.

Descrição

Código da peça: 01594000A

CRITO®CrossBoard

módulo de conexão

grampo 150 mm²

3 polos

connection top and bottom

para CrossBoard 500 - 1100 mm

NEW

Sistema

CrossBoard®

Grupo de produto 07
Subgroup 48
UE 1
EAN 4021267015947
ECLASS 6.1 27141146
ECLASS 7.1 27141146
ETIM 4.0 EC000001
ETIM 5.0 EC000001

Aprovações

Standards

IEC 61439-1:2011
IEC 60999-1:1999
IEC 60999-2:2003

UL 508

Approvals

UL , EAC

for UL feeder circuits >250V

Número de tipo: CR-B-114-A2

EAC Type: TE-M

UL file: E123577, UL category (for USA): NMTR https://www.ul.com

UL file: E123577, UL category (for Canada): NMTR7 https://www.ul.com

Aprovação CCC: no certification required

Dados técnicos

Dados IEC
Standards
IEC 61439-1:2011
IEC 60999-1:1999
IEC 60999-2:2003
Dados elétricos IEC
Corrente de medição (IEC): 320 A
Tensão de medição (IEC) AC: 690 V
Tensão nominal de isolamento: 800 V
Tensão suportável nominal de impulso Uimp: 6 kV
The insulation performance of the article depends on the installation conditions.
rated peak withstand current  Ipk max.: 40 kA
Dados adicionais IEC

The following values have been verified with tests under certain conditions. Please ask Wöhner for this conditions before designing your panel.

tensão máxima IEC AC: 800 V
tensão máxima IEC DC: 800 V
current capacity (IEC) max.: 320 A
Dados UL
Standards
UL 508
for UL feeder circuits >250V
suitable for field-installed conductors
Dados electricos UL
rated current (UL): 285 A
rated voltage (UL) AC: 600 V
rated frequency (UL): 50 / 60 Hz
for wires UL: Cu 75°C
SCCR unprotected max.: 10 kA
3 cycles (without OPD) @ 600 V AC
SCCR protected max.: 100 kA
SCCR: 65 kA with any DIVQ/7 circuit breaker 400 A / 480 V AC
100 kA with JDDZ fuse Class J 400 A / 600 V AC
Dados mecânicos
L x A x P: 114 x 276 x 57
Peso: 94,8 kg/100
Polaridade: 3 polos
front degree of protection: IP20
pontos terminais
screw clamp connection
screw drive: S4
wire stripping: 30 mm
min. cross-section: 35 mm²
max. cross-section: 150 mm²
Md min.: 4,0 Nm
Md max.: 6,0 Nm
Suitable for aluminium cables.
When using aluminium cables, observe the maintenance instructions.
  
min. cross-section UL: AWG 2
max. cross-section UL: MCM 300
torque (UL): 35 - 53 lb-in
for wires UL: Cu 75°C
  

Connecting circular conductors:

35... 50 mm² / 2... 1/0 AWG

4Nm / 35 lb in

 

70... 150 mm² / 2/0 AWG... 300 kcmil

6Nm / 53 lb in

 

35... 95 mm² flexible conductors, circular stranded conductors, flexible conductors with wire-end ferrules DIN 46228-1 max. 30 mm

120... 150 mm² flexible and circular stranded conductors

 

Connecting flexible conductors:

4x - 10x 15,5mm  x 0,8 mm

6Nm / 53 lb in  

Links

Downloads

Acessórios

01654000A
tampa de proteção IP20 contra toque
for round conductors
para: 01594, 01595
NEW
Mais

01655000A
tampa de proteção IP20 contra toque
for flat conductors
para: 01594, 01595
NEW
Mais

Encontre sua pessoa de contato

Para a página de contato

Wöhner Sistemas
Eletrotécnicos Ltda.
Rua Antônio Galvão Pacheco, 185
18550-612, Boituva/SPl
Brasil

Linha direta de pedidos (Alemanha)
+49 9563 751 125
order@woehner.de

Linha direta de tecnologia (Alemanha)
+49 9563 751 508
support@woehner.com

Produtos Configurador Current metal surcharges folder for files