Inovações
Produtos
A imagem pode mostrar um produto similar.
Código da peça: 31133000
AMBUS®Panel
suporte para fusíveis cilíndricos, com LED
10 x 38 / 3P
32 A / 110 - 690 V
indication of a released fuse link
for mounting rail
Sistema
Panel
Vantagens do produto
large clamping range
holder for label
Grupo de produto | 17 |
Subgroup | 06 |
Unidade por pacote | 4 |
EAN | 4021267311339 |
ECLASS 6.1 | 27142190 |
ECLASS 7.1 | 27142190 |
ETIM 4.0 | EC002705 |
ETIM 5.0 | EC002705 |
Standards
IEC 60947-1:2020
IEC 60947-3:2020 AC ratings only
UL 4248-1
Approvals
IEC (CB) , CSA , UL , CCC
for UL feeder circuits >250V
Número de tipo: AES10x38
UL file: E230163, UL category (for USA): IZLT https://www.ul.com
UL file: E230163, UL category (for Canada): IZLT7 https://www.ul.com
CSA file: 110285, CSA class: 6225-01 https://directories.csa-international.org
CCC certificate: 2012010302581751
for fuse links size: | 10x38 |
fuse links acc. to standard: | IEC / HD 60269-2 |
permitted power dissipation of the fuse-link: | 3 W |
Dados IEC | |
Standards | |
IEC 60947-1:2020 IEC 60947-3:2020 AC ratings only |
Dados elétricos IEC | |
Corrente de medição (IEC): | 32 A |
Tensão de medição (IEC) AC: | 690 V |
min. operating voltage AC: | 110 V |
Tensão nominal de isolamento: | 690 V |
Tensão suportável nominal de impulso Uimp: | 6 kV |
Utilisation category AC (IEC 60947-3) : | AC-22B (400V) |
cond. short-circuit current with fuses (AC): | 100 kA / 400 V (32A) |
100 kA / 500 V (25A) | |
approved wth fuse links of operation class: | gG |
Dissipação de energia do artigo:
A dissipação de energia em uma carga de 80% resulta em 0,6 W.
(A dissipação de energia em sua carga máxima seria 0,9 W.)
Dados adicionais IEC | |
The following values have been verified with tests under certain conditions. Please ask Wöhner for this conditions before designing your panel. |
tensão máxima IEC AC: | 725 V |
further utilisation category AC (IEC 60947-3): | AC-20B (1000 V) at pollution degree 2 |
A fuse-combination unit acc. to IEC 60947-3 can only be operated at a higher voltage than its rated voltage, if it is used as a fuse-disconnector without breaking capacity, up to its max. rated insulation voltage and labelled as such. |
for fuse links as per IEC / EN 60269-2 with permitted rated power dissipations up to max. 3W for gG/gL up to max. 1.2W for aM |
Dados UL | |
Standards | |
UL 4248-1 |
for UL feeder circuits >250V | |
suitable for field-installed conductors |
Dados electricos UL | |
corrente nominal (UL): | 30 A |
rated voltage (UL) AC: | 600 V |
min. operating voltage AC: | 110 V |
rated frequency (UL): | 50 / 60 Hz |
tensão nominal (UL) DC: | 600 V |
for wires UL: | Cu 75°C |
SCCR: | 100 kA |
Dados mecânicos | |
L x A x P: | 54 x 81 x 58 |
Peso: | 17,0 kg/100 |
Polaridade: | 3 polos |
Montagem: | for mounting rail |
degree of protection: | IP20 |
front degree of protection: | IP20 |
pontos terminais | |
cage clamp connection | |
screw drive: | PZ2 |
wire stripping: | 11 mm |
min. cross-section: | 0,75 mm² |
max. cross-section: | 25 mm² |
Md min.: | 2,0 Nm |
Md max.: | 2,5 Nm |
Not suitable for aluminium cables ! | |
min. cross-section UL: | AWG 18 |
max. cross-section UL: | AWG 4 |
torque (UL): | 18 - 22 lb-in |
for wires UL: | Cu 75°C |
for applications acc. to IEC / EN : |
Not suitable for aluminium cables ! | |
A fuse-combination unit acc. to IEC 60947-3 can only be operated at a higher voltage than its rated voltage, if it is used as a fuse-disconnector without breaking capacity, up to its max. rated insulation voltage and labelled as such. | |
Notas |
The indicator light signals that the fuse has tripped, but only when the closed fuse-holder is under voltage. |
permitted power dissipation of the fuse-link: | 3 W |
for UL feeder circuits >250V |