Inovações
Produtos
for UL feeder circuits >250V
A imagem pode mostrar um produto similar.
Código da peça: 01593000A
CRITO®CrossBoard
módulo de conexão
com prensa-cabos 6 - 50 mm² / AWG 10 - AWG 1
3 polos
Sistema
CrossBoard® 125A / 250A
Vantagens do produto
direct connection to the CrossBoard, cover included
capable of feeding (up to 125 A) 1 or 2 CrossBoards simultaneously with balanced or unbalanced load on the boards.
can be used without cables as a bridge connection between 2 CrossBoards up to 125 A. Feeding a third CrossBoard with cables is acceptable, but the total current cannot exceed 125 A.
touch-safe
CRITO® unlockable from top or bottom
Grupo de produto | 07 |
Subgroup | 42 |
Unidade por pacote | 1 |
EAN | 4021267015930 |
ECLASS 6.1 | 27141146 |
ECLASS 7.1 | 27141146 |
ETIM 4.0 | EC000001 |
ETIM 5.0 | EC000001 |
Standards
IEC 61439-1:2020
IEC 60999-1:1999
IEC 60999-2:2003
UL 508
Approvals
UL
for UL feeder circuits >250V
Número de tipo: CR45-A
UL file: E123577, UL category (for USA): NMTR https://www.ul.com
UL file: E123577, UL category (for Canada): NMTR7 https://www.ul.com
Aprovação CCC: no certification required
Dados IEC | |
Standards | |
IEC 61439-1:2020 IEC 60999-1:1999 IEC 60999-2:2003 |
Dados elétricos IEC | |
Corrente de medição (IEC): | 125 A |
Tensão de medição (IEC) AC: | 690 V |
Tensão nominal de isolamento: | 800 V |
rated peak withstand current Ipk max.: | 15 kA |
Dados adicionais IEC | |
The following values have been verified with tests under certain conditions. Please ask Wöhner for this conditions before designing your panel. |
tensão máxima IEC AC: | 800 V |
tensão máxima IEC DC: | 800 V |
current capacity (IEC) max.: | 125 A |
Dados UL | |
Standards | |
UL 508 |
for UL feeder circuits >250V | |
suitable for field-installed conductors |
Dados electricos UL | |
corrente nominal (UL): | 100 A |
rated voltage (UL) AC: | 600 V |
rated frequency (UL): | 50 / 60 Hz |
SCCR unprotected max.: | 10 kA |
3 cycles (without OPD) @ 600 V AC | |
SCCR protected max.: | 100 kA |
SCCR: |
65 kA with any DIVQ/7 circuit breaker 100 A / 600 V AC
100 kA with any DIVQ/7 circuit breaker 100 A / 480 V AC 100 kA with JDDZ fuse Class J 175 A / 600 V AC |
Dados mecânicos | |
L x A x P: | 45 x 160 x 92 |
Peso: | 25,0 kg/100 |
Polaridade: | 3 polos |
front degree of protection: | IP20 |
pontos terminais | |
cage clamp connection | |
screw drive: | S4 |
wire stripping: | 17 mm |
min. cross-section: | 6 mm² |
max. cross-section: | 50 mm² |
Md min.: | 5,0 Nm |
Md max.: | 6,0 Nm |
min. cross-section UL: | AWG 10 |
max. cross-section UL: | AWG 1/0 |
torque (UL): | 44 - 53 lb-in |
6 - 50 mm² / AWG 10 - AWG 1 (feindrähtig mit Aderendhülse eventuell nicht mit maximalen Querschnitt möglich) |
The insulation performance of the article depends on the installation conditions. | |
for UL feeder circuits >250V |
Encontre sua pessoa de contato
Para a página de contato
Wöhner Sistemas
Eletrotécnicos Ltda.
Rua Antônio Galvão Pacheco, 185
18550-612, Boituva/SPl
Brasil
Linha direta de pedidos (Alemanha)
+49 9563 751 125
order@woehner.de
Linha direta de tecnologia (Alemanha)
+49 9563 751 508
support@woehner.com