Innovazioni
            
        
        
      
        
            Prodotti
            
        
      	
        
        
        
    The picture may show a similar product.
Cod.art.: 32150 000A
EQUES®60Classic
Adattatore 570 A, 3p
140 x 270
coll. al sistema in alto o basso
per Noark Ex9M3
per barre 12, 15, 20, 25, 30 x 5, 10 e barre profilate
NUOVO
Montaggio
60Classic
| gruppo di prodotto | 05 | 
| sottogruppo prodotto | 42 | 
| pz/ conf. | 1 | 
| EAN | 4021267321505 | 
| ECLASS 6.1 | 27370304 | 
| ECLASS 7.1 | 27370304 | 
| ETIM 4.0 | EC001531 | 
| ETIM 5.0 | EC001531 | 
Norme
IEC 61439-1:2020
UL 508
Omologazioni
CSA , UL
																		
																		
for UL feeder circuits >250V
type no.: 60630.1-L
UL file: E123577, UL category (for USA): NMTR https://www.ul.com
UL file: E123577, UL category (for Canada): NMTR7 https://www.ul.com
CSA file: 110285, CSA class: 3211-37 https://directories.csa-international.org
Omologazione CCC : no certification required
| Details IEC | |
| Norme | |
| IEC 61439-1:2020 | 
| Electrical data IEC | |
| corrente nominale (IEC): | 570 A | 
| tensione nominale (IEC) AC: | 690 V | 
| tensione nominale di isolamento Ui AC: | 800 V | 
| tensione di picco Uimp: | 6 kV | 
| 
																 NS 630: 35 kA @ 600 V / Id = 37 kA  | 
														
power dissipation of the article:
The power dissipation at a typical load of 80 % results to 25,7 W.
(The power dissipation at full load would be 40,2 W.)
| Details UL | |
| Norme | |
| UL 508 | 
| for UL feeder circuits >250V | 
| Electrical data UL | |
| corrente nominale (UL): | 600 A | 
| tensione nominale (UL) AC: | 600 V | 
| frequenza nominale (UL): | 50 / 60 Hz | 
| SCCR protected max.: | 65 kA | 
| SCCR: | 
																			
																			65 kA with DIVQ/7 600 A / 480 V AC
																			 50 kA with DIVQ/7 600 A / 600 V AC  | 
																
| Valori meccanici | |
| L x A x P: | 140 x 270 x 35 | 
| peso: | 222,6 kg/100 | 
| Poli: | 3 poli | 
| per barre: | 12, 15, 20, 25, 30 x 5, 10 e barre profilate | 
| There must be a clearance of at least 10 mm above the article to remove it from the busbar system. | |
| 
																 the short-circuit capacity of the combination of adapter and MCCB depends on the MCCB  | 
														|
| for UL feeder circuits >250V | 
Trova il tuo contatto
to the contact site
Wöhner GmbH & Co. KG
Elektrotechnische Systeme
Mönchrödener Str. 10
96472 Rödental
Order hotline (Germany)
+49 9563 751 161
order@woehner.de
Technical hotline (Germany)
+49 9563 751 260
support@woehner.com