réglette sectionneur à fusible 400 A (37527)

The picture may show a similar product.

Description

Référence 37527000A

QUADRON®185Power

réglette sectionneur à fusible 400 A

taille 2, commutation à 1 pôle

V-clamp 120 mm²

terminal body alu, pressure piece brass

prewired with 3x measuring transformers 400 A / 333 mV, accuracy class 1, with lead RJ12 (3,00 m)

pour jeux de barres 30, 40, 60, 80, 100, 120 x 10

coming soon

Système

185Power

Avantages produit

Self-closing inspection holes are available in the cover.

Cover can be locked when closed.

Groupe de produits 12
Sous-groupe 64
Dimensions de l'emballage 1
EAN 4021267375270
ECLASS 6.1 27142108
ECLASS 7.1 27142108
ETIM 4.0 EC001046
ETIM 5.0 EC001046

Homologations

Normes

IEC 60947-1:2020
IEC 60947-3:2020 AC ratings only

Approbations

IEC (CB)

Type: QU185-2 Pre-Assembled

Données techniques

for fuse links size: NH 2
fuse links acc. to standard: IEC / HD 60269-2
permitted power dissipation of the fuse-link: 34 W
requirements for contact parts: Fuse links with silver-plated contact pieces recommended.
For fuse links with nickel-plated contact pieces, a reduction factor of 0.8 is to be observed.
Details IEC
Normes
IEC 60947-1:2020
IEC 60947-3:2020 AC ratings only
Electrical data IEC
Courant assigné (IEC): 400 A
Tension assignée (IEC) CA: 800 V
rated isolation voltage Ui AC: 1000 V
Tension assignée de tenue aux chocs Uimp: 12 kV
Catégorie d'emploi CA:

AC-22B (800 V / 200 A)
AC-22B (690 V / 400 A)
AC-23B (400 V / 400 A)

Catégorie d'emploi CC: DC-20B
max. voltage between the fuses: 1000V
visible information required: Do not switch under load.
cond. short-circuit current with fuses (AC): 100 kA / 690 V (400 A)
120 kA / 400 V (400 A)
65 kA / 800 V (200A)
approved wth fuse links of operation class: gG

power dissipation of the article:

The power dissipation at a typical load of 80 % results to 38,4 W.

(The power dissipation at full load would be 60,0 W.)

Supplementary data IEC

Les valeurs suivantes ont été vérifiées par des tests sous certaines conditions. Veuillez demander ces conditions à Wöhner avant de concevoir votre armoire.

Les unités de commutation à fusibles conformes à la norme IEC 60947-3 ne peuvent fonctionner au-delà de la tension de service nominale que si elles sont utilisées comme sectionneurs à fusible sans fonction de commutation de charge et cela jusqu'à la tension d'isolement assignée et sont marquées en conséquence.
Besondere Betriebsbedingungen gemäß IEC / EN 61439-1 können zu Fehlauslösungen von Meldeschaltern oder Sicherungsüberwachungen führen. Die vorliegenden Betriebsbedingungen sind dementsprechend bei der Auswertung der Meldesignale zu berücksichtigen.
Degree of protection IP20 at front, degree of protection near terminal depends on installation
Charactéristiques mécaniques
L x H x P: 100 x 687 x 189
Poids: 543,0 kg/100
Pôles: 3 pôles
pour jeux de barres: 30, 40, 60, 80, 100, 120 x 10
CT can be integrated in the device: ja
CT can be integrated in the CT module: nein
front degree of protection: IP20
degree of protection when open: IP10

Type of fastening:
can be screwed onto drilled busbar, diameter 13mm, undrilled mounting with terminal clamp
connection:
screw connection M12

Points de raccordement
v-clamp
min. cross-section: 25 mm²
max. cross-section: 240 mm²
re: 25 - 95 mm²
rm: 25 - 150 mm²
se: 35 - 240 mm²
sm: 35 - 185 mm²
Suitable for aluminium conductors.
the temperature of aluminium conductors must not exceed 80°C (see operating instructions)
pre-treatment of aluminium conductors: see general technical information (under Downloads)

Application notes

Suitable for aluminium conductors.
the temperature of aluminium conductors must not exceed 80°C (see operating instructions)
pre-treatment of aluminium conductors: see general technical information (under Downloads)
Les unités de commutation à fusibles conformes à la norme IEC 60947-3 ne peuvent fonctionner au-delà de la tension de service nominale que si elles sont utilisées comme sectionneurs à fusible sans fonction de commutation de charge et cela jusqu'à la tension d'isolement assignée et sont marquées en conséquence.

Conseils

The terminal compartment cover 33733 is always needed for the connection at top and when using cable lugs.

permitted power dissipation of the fuse-link: 34 W
requirements for contact parts: Fuse links with silver-plated contact pieces recommended.
For fuse links with nickel-plated contact pieces, a reduction factor of 0.8 is to be observed.

Links

Documentation

Accessoires

33740000A
étrier de serrage
pour des jeux de barres sans caches de protection
taille 1 - 3
Plus

33733000A
cache-bornier
universel pour réglettes NH, taille 1 - 3 et réglette de raccordement 800 A
taille 1 - 3
Plus

33564000A
V-clamp
terminal body alu, pressure piece brass
for PEN
for Cu / Al 120 - 300 mm²
coming soon
Plus

33738000A
étrier de serrage CrossLink®
pour des jeux de barres avec protection CrossLink® contre les contacts accidentels
taille 1 - 3
Plus

33156000
contact de signalisation
commutateur 250 V AC / 5 A, 30 V DC / 4 A
Plus

33758000A
obturateur latéral
pour caches frontaux
taille 00 - 3
Plus

33558000A
V-clamp
without cover cap
terminal body alu, pressure piece brass
taille 1-3
for Cu / Al 120 - 300 mm²
coming soon
Plus

Trouver votre contact

to the contact site

Wöhner GmbH & Co. KG
Elektrotechnische Systeme
Mönchrödener Str. 10
96472 Rödental

Order hotline (Germany)
+49 9563 751 161
order@woehner.de

Technical hotline (Germany)
+49 9563 751 260
support@woehner.com