L'Entreprise
Innovationen
Produits
The picture may show a similar product.
Référence 32781000A
EQUES®185Power
adaptateur de jeu de barres, 1200 A
300 x 652, connexion par le haut / par le bas, liaison vissée
pour Eaton NZM4 (1250 A)
pour jeux de barres 30, 40, 60, 80, 100, 120 x 10
not suitable for systems with CrossLink protection modules
Système
185Power
Groupe de produits | 05 |
Sous-groupe | 48 |
Dimensions de l'emballage | 1 |
EAN | 4021267327811 |
ECLASS 6.1 | 27370304 |
ECLASS 7.1 | 27370304 |
ETIM 4.0 | EC001531 |
ETIM 5.0 | EC001531 |
Normes
IEC 61439-1:2020
UL 508
Approbations
UL
for UL feeder circuits >250V
Type: EQ185-A1600-S
UL file: E123577, UL category (for USA): NMTR https://www.ul.com
UL file: E123577, UL category (for Canada): NMTR7 https://www.ul.com
Homologation CCC: no certification required
Details IEC | |
Normes | |
IEC 61439-1:2020 |
Electrical data IEC | |
Courant assigné (IEC): | 1200 A |
Tension assignée (IEC) CA: | 690 V |
Tension assignée (IEC) CC: | 800 V |
rated isolation voltage Ui AC: | 1000 V |
rated isolation voltage Ui DC: | 1000 V |
Tension assignée de tenue aux chocs Uimp: | 12 kV |
rated peak withstand current Ipk max.: | 106 kA |
rated short-time withstand current Icw (1.0 s) max.: | 50 kA |
power dissipation of the article:
The power dissipation at a typical load of 80 % results to 233,6 W.
(The power dissipation at full load would be 365,0 W.)
mit Eaton NZM4 1250A bis 1200A Verbindung unten einsetzbar! mit Schrack MC4 1250A bis 1200A Verbindung unten einsetzbar! mit Eaton NZM4 1250A bis 1250A Verbindung oben einsetzbar! mit Schrack MC4 1250A bis 1250A Verbindung oben einsetzbar! |
Details UL | |
Normes | |
UL 508 |
for UL feeder circuits >250V |
Electrical data UL | |
rated current (UL): | 1200 A |
rated voltage (UL) AC: | 1000 V |
rated frequency (UL): | 50 / 60 Hz |
SCCR unprotected max.: | 50 kA |
3 cycles (without OPD) @ 1000 V AC |
Charactéristiques mécaniques | |
L x H x P: | 300 x 652 x 85 |
Poids: | 2600,0 kg/100 |
Pôles: | 3 pôles |
pour jeux de barres: | 30, 40, 60, 80, 100, 120 x 10 |
CT can be integrated in the device: | ja |
Conseils |
Ausreichend Platz für 2x3 Stromwandler vorhanden. |
short-circuit withstandability: | the short-circuit capacity of the combination of adapter and MCCB depends on the MCCB |
for UL feeder circuits >250V |
Trouver votre contact
to the contact site
Wöhner GmbH & Co. KG
Elektrotechnische Systeme
Mönchrödener Str. 10
96472 Rödental
Order hotline (Germany)
+49 9563 751 161
order@woehner.de
Technical hotline (Germany)
+49 9563 751 260
support@woehner.com