Part No.: 32036000A

EQUES®60Classic

adaptador para embarrado de 32 A

44 x 200, with plug-in connection 3RV29 (Siemens)

para Siemens S00, S0

para barras 12, 15, 20, 25, 30 x 5, 10 y barras perfiladas

NEW

sistema

60Classic

ventajas del producto

Werkzeuglose Kontaktierung zum Schaltgerät mit Stecker 3RV29
Rastmechanismus beim Aufschieben auf die Sammelschiene.

grupo de producto 05
subgrupo 21
embalaje 4
EAN 4021267320362
ECLASS 6.1 27370304
ECLASS 7.1 27370304
ETIM 4.0 EC001531
ETIM 5.0 EC001531

Homologaciónes

Normas

IEC 61439-1:2020

UL 508

homologaciónes

CSA , UL

for UL feeder circuits >250V

tipo: EEC6025-P

UL file: E123577, UL category (for USA): NMTR https://www.ul.com

UL file: E123577, UL category (for Canada): NMTR7 https://www.ul.com

CSA file: 110285, CSA class: 3211-37 https://directories.csa-international.org

Homologación CCC: no es obligatoria la certificación

Datos técnicos

datos IEC
Normas
IEC 61439-1:2020
datos electricos IEC
intensidad de corriente nominal (IEC): 32 A
tensión nominal (IEC) AC: 690 V
tensión nominal de aislamiento Ui AC: 800 V
tensión de pico Uimp: 6 kV

disipación de potencia del articulo:

The power dissipation at a typical load of 80 % results to 1,6 W.

(The power dissipation at full load would be 2,5 W.)

datos UL
Normas
UL 508
for UL feeder circuits >250V
datos electricos UL
intensidad de corriente nominal (UL): 32 A
tensión nominal (UL) AC: 600 V
frecuencia nominal (UL): 50 / 60 Hz
SCCR protected max.: 65 kA
SCCR: 30 kA with 3RV2.1/2.2 up to 12,5 A in combination with upstream JDDZ fuse Class J 100 A/ 600 V AC
65 kA with 3RV2.1/2.2 up to 25 A / 480 V AC
65 kA with 3RV2.1/2.2 up to 16 A / 480 V AC
50 kA with 3RV2.1/2.2 up to 32 A in combination with upstream JDDZ fuse Class J 100 A/ 480 V AC
datos mecánicos
An x A x P: 45 x 200 x 80
peso: 26,5 kg/100
Polaridad: 3 polos
para barras: 12, 15, 20, 25, 30 x 5, 10 y barras perfiladas

Application notes

There must be a clearance of at least 12 mm above the article to remove it from the busbar system.
short-circuit withstandability: the short-circuit capacity of the combination of adapter and motor starter depends on the motor starter