Innovaciones
Productos
La imagen puede mostrar un producto similar.
Part No.: 01401 000
CRITO®30Compact
Placa de bornes de conexión, 3 polos
6 - 50 mm², AWG 10 - 2/0, lam. Cu.
para barras 12 x 5, 10
sistema
30Compact 3P
ventajas del producto
Terminals can be removed for connection of uncut conductors
| grupo de producto | 07 |
| subgrupo | 42 |
| embalaje | 1 |
| EAN | 4021267014018 |
| ECLASS 6.1 | 27141146 |
| ECLASS 7.1 | 27141146 |
| ETIM 4.0 | EC000001 |
| ETIM 5.0 | EC000001 |
Normas
IEC 61439-1:2020
IEC 60999-1:1999
IEC 60999-2:2003
UL 508
homologaciónes
UL , DNV GL
for UL feeder circuits >250V
tipo: 240C-L
UL file: E123577, UL category (for USA): NMTR https://www.ul.com
UL file: E123577, UL category (for Canada): NMTR7 https://www.ul.com
Homologación CCC: no es obligatoria la certificación
| datos IEC | |
| Normas | |
|
IEC 61439-1:2020 IEC 60999-1:1999 IEC 60999-2:2003 |
| datos electricos IEC | |
| intensidad de corriente nominal (IEC): | 175 A |
| tensión nominal (IEC) AC: | 690 V |
| resistencia a corriente de pico Ipk máx. : | 40.5 kA |
| datos adicionales IEC | |
|
Los siguientes valores han sido verificados con los test bajo ciertas condiciones. Por favor, pregunte a Wöhner por estas condiciones antes de diseñar su cuadro. |
| tensión máxima (IEC) AC: | 1000 V |
| tensión máxima (IEC) DC: | 1500 V |
| máxima intensidad de corriente (IEC): | 300 A |
| datos UL | |
| Normas | |
| UL 508 |
| for UL feeder circuits >250V | |
| suitable for field-installed conductors |
| datos electricos UL | |
| intensidad de corriente nominal (UL): | 175 A |
| tensión nominal (UL) AC: | 600 V |
| frecuencia nominal (UL): | 50 / 60 Hz |
| datos mecánicos | |
| An x A x P: | 54 x 160 x 84 |
| peso: | 20,6 kg/100 |
| Polaridad: | 3 polos |
| para barras: | 12 x 5, 10 |
| puntos de apriete | |
| cage clamp connection | |
| wire stripping: | 25 mm |
| min. cross-section: | 6 mm² |
| max. cross-section: | 50 mm² |
| rm: | 6 - 50 mm² |
| f: | 6 - 50 mm² |
| f + AE: | 6 - 50 mm² |
| (f + AE may not fit with max. cross-section) | |
| Md min.: | 8,0 Nm |
| Md max.: | 10,0 Nm |
| Not suitable for aluminium cables ! | |
| lam. Cu width: | 7 - 9 mm |
| lam. Cu thickness: | 4 - 10 mm |
| number of lam. Cu: | 1 |
| min. cross-section UL: | AWG 10 |
| max. cross-section UL: | AWG 2/0 |
| torque (UL): | 71 lb-in |
| Not suitable for aluminium cables ! | |
| La capacidad de aislamiento del artículo depende de las condiciones de la instalación. | |
| for UL feeder circuits >250V |
Busca tu contacto
a la pagina de contactos
Wöhner GmbH & Co. KG
Elektrotechnische Systeme
Mönchrödener Str. 10
96472 Rödental
Order hotline (Germany)
+49 9563 751 161
order@woehner.de
Technical hotline (Germany)
+49 9563 751 260
support@woehner.com