Company
Innovationen
Products
The picture may show a similar product.
Part No.: 32416000
EQUES®60Classic
busbar adapter 45 A
2 adjustable mounting rails
54 x 260, with removable upper section and leads AWG 8 (10 mm²)
for busbars 12, 15, 20, 25, 30 x 5, 10 and section busbars
with CrossLink®Technology
System
60Classic
Advantages of the product
Conductor ends ultrasonically sealed.
Click mechanism when pushing onto the busbar.
Product group | 05 |
Subgroup | 22 |
pack size | 4 |
EAN | 4021267324162 |
ECLASS 6.1 | 27370304 |
ECLASS 7.1 | 27370304 |
ETIM 4.0 | EC001531 |
ETIM 5.0 | EC001531 |
Standards
IEC 61439-1:2020
UL 508
Approvals
CSA , UL , DNV GL
for UL feeder circuits >250V
type number: EMC6045-L
UL file: E123577, UL category (for USA): NMTR https://www.ul.com
UL file: E123577, UL category (for Canada): NMTR7 https://www.ul.com
CSA file: 110285, CSA class: 3211-37 https://directories.csa-international.org
CCC approval: no certification required
Details IEC | |
Standards | |
IEC 61439-1:2020 |
Electrical data IEC | |
rated current (IEC): | 45 A |
rated voltage (IEC) AC: | 690 V |
rated isolation voltage Ui AC: | 800 V |
rated surge voltage Uimp : | 6 kV |
power dissipation of the article:
The power dissipation at a typical load of 80 % results to 3.5 W.
(The power dissipation at full load would be 5.5 W.)
Details UL | |
Standards | |
UL 508 |
for UL feeder circuits >250V |
Electrical data UL | |
rated current (UL): | 45 A |
rated voltage (UL) AC: | 600 V |
rated frequency (UL): | 50 / 60 Hz |
SCCR protected max.: | 65 kA |
SCCR: | 65kA with any DIVQ/7 circuit breaker 40A / 480V AC |
Mechanical data | |
W x H x D: | 54 x 260 x 75 |
weight: | 56.7 kg/100 |
poles: | 3-pole |
for busbars: | 12, 15, 20, 25, 30 x 5, 10 and section busbars |
There must be a clearance of at least 12 mm above the article to remove it from the busbar system. | |
Reference |
For compact mounting of complete motor circuits with commercially available switchgear and safe mechanical and electrical connection to the busbar system. In the test position, the structure locks and disconnects safely from the primary energy supply. |
short-circuit withstandability: | the short-circuit capacity of the combination of adapter and motor starter depends on the motor starter |
for UL feeder circuits >250V |
Find your contact
to the contact site
Wöhner GmbH & Co. KG
Elektrotechnische Systeme
Mönchrödener Str. 10
96472 Rödental
Order hotline (Germany)
+49 9563 751 161
order@woehner.de
Technical hotline (Germany)
+49 9563 751 260
support@woehner.com