BROOME10®60Classic
power supply 10 A
400 V AC / 24 V DC, with push-in terminals
for busbars 12, 15, 20, 25, 30 x 5, 10 and section busbars
System
60Classic
Advantages of the product
Efficiency of 95% permits an intallation width of 45 mm
Self-protected at short-circuit with intelligent re-start
No pre-fuse needed
Overvoltage category III
| Product group | 21 |
| Subgroup | 42 |
| pack size | 1 |
| EAN | 4021267362027 |
| ECLASS 6.1 | 27142325 |
| ECLASS 7.1 | 27142325 |
| ETIM 4.0 | EC002540 |
| ETIM 5.0 | EC002540 |
Standards
IEC 61010-1:2010
IEC 61010-2-201:2013
UL 61010-1
UL 61010-2-201
Approvals
IEC (CB) , UL
for UL feeder circuits >250V
type number: BROOME10
UL file: E497002, UL category (for USA): NMTR. https://www.ul.com
UL file: E497002, UL category (for Canada): NMTR7. https://www.ul.com
| Details IEC | |
| Standards | |
|
IEC 61010-1:2010 IEC 61010-2-201:2013 |
| Electrical data IEC | |
| rated voltage (IEC) AC: | 480 V |
| min. operating voltage AC: | 380 V |
| output voltage DC: | 24 V |
| output current: | 10 A |
| voltage control: | No |
| typical hold-up time (400 V): | 20 ms |
| typical hold-up time (480 V): | 20 ms |
| separation input / output: | SELV / PELV |
| over-voltage protection: | 32 V |
| parallel operation possible: | Yes |
| serial operation possible: | Yes |
| rated frequency (IEC): | 50 / 60 Hz |
| rated isolation voltage Ui AC: | 500 V |
| rated surge voltage Uimp : | 4 kV |
| Further technical data: max. input inrush current: 1,5 A periodic and random deviation: 50 mVpp hold-up time (typical): 20 ms input / output separation: SELV / PELV output overvoltage protection: max. 32 V dc parallel installation to increase the power: up to 30 A without additional protection for more than 30 A each output has to be protected by a fuse 16 A serial installation to increase the voltage: up to 72 V dc (note: Ab at 60 V dc and more: no SELV) |
| Details UL | |
| Standards | |
|
UL 61010-1
UL 61010-2-201 |
| for UL feeder circuits >250V |
| Electrical data UL | |
| rated voltage (UL) AC: | 480 V |
| min. operating voltage AC: | 380 V |
| rated frequency (UL): | 50 / 60 Hz |
| Mechanical data | |
| W x H x D: | 45 x 200 x 172 |
| weight: | 71,8 kg/100 |
| poles: | 2-pole |
| for busbars: | 12, 15, 20, 25, 30 x 5, 10 and section busbars |
| degree of protection: | IP30 |
| vertical installation position: | Yes |
| horizontal installation position: | No |
| Terminal points | |
| push-in connection | |
| AWG14 (2,5 mm²) | |
| screw drive: | 0,5x3 |
| wire stripping: | 10 mm |
| min. cross-section: | 0,2 mm² |
| max. cross-section: | 2,5 mm² |
| min. cross-section UL: | AWG 24 |
| max. cross-section UL: | AWG14 |
|
push-in terminal: |
|
| for UL feeder circuits >250V |
Find your contact
to the contact site
Wöhner GmbH & Co. KG
Elektrotechnische Systeme
Mönchrödener Str. 10
96472 Rödental
Order hotline (Germany)
+49 9563 751 161
order@woehner.de
Technical hotline (Germany)
+49 9563 751 260
support@woehner.com