busbar adapter 250 A, 4-pole (32586)

The picture may show a similar product.

Description

Part No.: 32586 000A

EQUES®60Classic

busbar adapter 250 A, 4-pole

140 x 270

N on left side

connection to the system top

for ABB Tmax XT3, XT4, Allen-Bradley 140G-J

for busbars 12, 15, 20, 25, 30 x 5, 10 and section busbars

System

60Classic

Product group 05
Subgroup 36
pack size 1
EAN 4021267325862
ECLASS 6.1 27370304
ECLASS 7.1 27370304
ETIM 4.0 EC001531
ETIM 5.0 EC001531
ETIM 8.0 EC001531

Approvals

Standards

IEC 61439-1:2020

UL 508

Approvals

CSA , UL , DNV GL

for UL feeder circuits >250V

type number: EPC60250-L

UL file: E123577, UL category (for USA): NMTR https://www.ul.com

UL file: E123577, UL category (for Canada): NMTR7 https://www.ul.com

CSA file: 110285, CSA class: 3211-37 https://directories.csa-international.org

CCC approval: no certification required

Technical data

Details IEC
Standards
IEC 61439-1:2020
Electrical data IEC
rated current (IEC): 250 A
rated voltage (IEC) AC: 690 V
rated isolation voltage Ui AC: 800 V
rated surge voltage Uimp : 6 kV

power dissipation of the article:

The power dissipation at a typical load of 80 % results to 8.1 W.

(The power dissipation at full load would be 12.6 W.)

Supplementary data IEC

The following values have been verified with tests under certain conditions. Please ask Wöhner for this conditions before designing your panel.

min. permitted operation temperature -40
Details UL
Standards
UL 508
for UL feeder circuits >250V
Electrical data UL
rated current (UL): 250 A
rated voltage (UL) AC: 600 V
rated frequency (UL): 50 / 60 Hz
SCCR unprotected max.: 22 kA
3 cycles (without OPD) @ 600 V AC
SCCR protected max.: 200 kA
SCCR: 200 kA with 3VA61 150 A, 3VA62 250 A / 240 V AC
50 kA with 3VA61 150 A, 3VA62 250 A / 600 V AC
150 kA with 3VA61 150 A, 3VA62 250 A / 480 V AC
Mechanical data
W x H x D: 140 x 270 x 35
weight: 180.0 kg/100
poles: 3-pole+N
for busbars: 12, 15, 20, 25, 30 x 5, 10 and section busbars
Material properties
halogen-free: Yes

Application notes

There must be a clearance of at least 10 mm above the article to remove it from the busbar system.

the short-circuit capacity of the combination of adapter and MCCB depends on the MCCB

for UL feeder circuits >250V

Links

Downloads

Find your contact

to the contact site

Wöhner GmbH & Co. KG
Elektrotechnische Systeme
Mönchrödener Str. 10
96472 Rödental

Order hotline (Germany)
+49 9563 751 161
order@woehner.de

Technical hotline (Germany)
+49 9563 751 260
support@woehner.com