Company
Innovationen
Products
The picture may show a similar product.
Part No.: 31232000
SECUR®60Classic PowerLiner
busbar mounted switch-disconnector-fuse
for fuses 10x38 IEC 60269-2
3P
connection bottom
for busbars 12, 15, 20, 25, 30 x 5, 10 and section busbars
3-pole / 1-pole switching
System
60Classic
Product group | 01 |
Subgroup | 42 |
pack size | 1 |
EAN | 4021267312329 |
ECLASS 6.1 | 27142190 |
ECLASS 7.1 | 27142190 |
ETIM 4.0 | EC002705 |
ETIM 5.0 | EC002705 |
Standards
IEC 60947-1:2020
IEC 60947-3:2020 AC ratings only
type number: SPL-10x38
for fuse links size: | 10x38 |
fuse links acc. to standard: | IEC / HD 60269-2 |
permitted power dissipation of the fuse-link: | 3 W |
Details IEC | |
Standards | |
IEC 60947-1:2020 IEC 60947-3:2020 AC ratings only |
Electrical data IEC | |
rated current (IEC): | 32 A |
rated voltage (IEC) AC: | 690 V |
rated voltage (IEC) DC: | 110 V |
rated isolation voltage Ui AC: | 500 V |
rated isolation voltage Ui DC: | 250 V |
rated surge voltage Uimp : | 6 kV |
Utilisation category AC (IEC 60947-3) : | AC-23A (400 V) |
cond. short-circuit current with fuses (AC): | 50 kA / 400 V (32A) |
approved wth fuse links of operation class: | gG |
power dissipation of the article:
The power dissipation at a typical load of 80 % results to 3.4 W.
(The power dissipation at full load would be 5.3 W.)
Supplementary data IEC | |
The following values have been verified with tests under certain conditions. Please ask Wöhner for this conditions before designing your panel. |
max. permitted voltage (IEC) AC: | 725 V |
A fuse-combination unit acc. to IEC 60947-3 can only be operated at a higher voltage than its rated voltage, if it is used as a fuse-disconnector without breaking capacity, up to its max. rated insulation voltage and labelled as such. |
for fuse links gG and aM as per IEC / EN 60269-2 | |
The function of isolation between incoming and outgoing contacts is provided by the opening of the switching mechanism as required in the standard. |
Mechanical data | |
W x H x D: | 27 x 220 x 100 |
weight: | 76.0 kg/100 |
poles: | 3-pole |
for busbars: | 12, 15, 20, 25, 30 x 5, 10 and section busbars |
front degree of protection: | IP20 |
Type of fastening: patented click mechanism
Terminal points | |
cage clamp connection | |
screw drive: | PZ2 |
wire stripping: | 12 mm |
min. cross-section: | 1.5 mm² |
max. cross-section: | 16 mm² |
Md min.: | 2.0 Nm |
Md max.: | 2.5 Nm |
Not suitable for aluminium cables ! |
Not suitable for aluminium cables ! | |
A fuse-combination unit acc. to IEC 60947-3 can only be operated at a higher voltage than its rated voltage, if it is used as a fuse-disconnector without breaking capacity, up to its max. rated insulation voltage and labelled as such. | |
permitted power dissipation of the fuse-link: | 3 W |
Find your contact
to the contact site
Wöhner GmbH & Co. KG
Elektrotechnische Systeme
Mönchrödener Str. 10
96472 Rödental
Order hotline (Germany)
+49 9563 751 161
order@woehner.de
Technical hotline (Germany)
+49 9563 751 260
support@woehner.com