power supply 10 A (36202000A)

The picture may show a similar product.

Description

Part No.: 36202 000A

BROOME10 60Classic

power supply 10 A

400 V AC / 24 V DC, with push-in terminals

for busbars 12, 15, 20, 25, 30 x 5, 10 and section busbars

System

60Classic

Advantages of the product

Efficiency of 95% permits an intallation width of 45 mm
Self-protected at short-circuit with intelligent re-start
No pre-fuse needed
Overvoltage category III

Product group 21
Subgroup 42
pack size 1
EAN 4021267362027
ECLASS 14.0 27142325
ETIM 5.0 EC002540
ETIM 8.0 EC002540
ETIM 10.0 EC002540

Approvals

Standards

IEC 61010-1:2010
IEC 61010-2-201:2013

UL 61010-1

UL 61010-2-201

Approvals

IEC (CB) , UL

for UL feeder circuits >250V

type number: BROOME10

EAC Type: PS

UL file: E497002, UL category (for USA): NMTR. https://www.ul.com

UL file: E497002, UL category (for Canada): NMTR7. https://www.ul.com

Technical data

Details IEC
Standards
IEC 61010-1:2010
IEC 61010-2-201:2013
Electrical data IEC
rated voltage (IEC) AC: 480 V
min. operating voltage AC: 380 V
output voltage DC: 24 V
output current: 10 A
voltage control: No
typical hold-up time (400 V): 20 ms
typical hold-up time (480 V): 20 ms
separation input / output: SELV / PELV
over-voltage protection: 32 V
parallel operation possible: Yes
serial operation possible: Yes
rated frequency (IEC): 50 / 60 Hz
rated isolation voltage Ui AC: 500 V
rated surge voltage Uimp : 4 kV

power dissipation of the article:

The power dissipation at a typical load of 80 % results to 8,4 W.

(The power dissipation at full load would be 13,2 W.)

Supplementary data IEC

The following values have been verified with tests under certain conditions. Please ask Wöhner for this conditions before designing your panel.

min. permitted operation temperature -25°C
max. permitted operation temperature 70°C
min. permitted temperature for transport and storage -25°C
max. permitted temperature for transport and storage 70°C
Further technical data:

max. input inrush current: 1,5 A

periodic and random deviation: 50 mVpp

hold-up time (typical): 20 ms

input / output separation: SELV / PELV

output overvoltage protection: max. 32 V dc


parallel installation to increase the power:
up to 30 A without additional protection
for more than 30 A each output has to be protected by a fuse 16 A

serial installation to increase the voltage:
up to 72 V dc (note: Ab at 60 V dc and more: no SELV)
Details UL
Standards
UL 61010-1
UL 61010-2-201
for UL feeder circuits >250V
Electrical data UL
rated voltage (UL) AC: 480 V
min. operating voltage AC: 380 V
rated frequency (UL): 50 / 60 Hz
Mechanical data
W x H x D: 45 x 200 x 172
weight: 71,8 kg/100
poles: 2-pole
for busbars: 12, 15, 20, 25, 30 x 5, 10 and section busbars
degree of protection: IP30
for vertical busbar system: Yes
for horizontal busbar system: No
Terminal points
push-in connection
AWG14 (2,5 mm²)
screw drive: 0.5x3
wire stripping: 10 mm
min. cross-section: 0,2 mm²
max. cross-section: 2,5 mm²
  
min. cross-section UL: AWG 24
max. cross-section UL: AWG14
  

push-in terminal:
IEC:
up to 2.5 mm² re, f
up to 1.5 mm² f+AE

UL:
AWG 24 - AWG 12

Material properties
halogen-free: Yes

Application notes

for UL feeder circuits >250V

Links (Prices, CAD data)

Downloads

Accessories

spare parts

36207 000A
spare part busbar adapter 25 A
busbar adapter base
for busbars: 12, 15, 20, 25, 30 x 5, 10 and section busbars
More

Find your contact

to the contact site

Wöhner GmbH & Co. KG
Elektrotechnische Systeme
Mönchrödener Str. 10
96472 Rödental

Order hotline (Germany)
+49 9563 751 161
order@woehner.de

Technical hotline (Germany)
+49 9563 751 260
support@woehner.com