Company
Innovationen
Products
The picture may show a similar product.
Part No.: 33356000
CAPUS®Panel
switch-disconnector 3-pole
screw M10, red handle
400 A
for mounting plate
System
Panel
Advantages of the product
double-breaking main contacts, visible separation sections, user-independent switching, assembly and connection material contained in scope of delivery
Product group | 14 |
Subgroup | 06 |
pack size | 1 |
EAN | 4021267333560 |
ECLASS 6.1 | 27371403 |
ECLASS 7.1 | 27371403 |
ETIM 4.0 | EC000216 |
ETIM 5.0 | EC000216 |
Standards
IEC 60947-1:2020
IEC 60947-3:2020 AC ratings only
Approvals
IEC (CB)
type number: LTS-400
Details IEC | |
Standards | |
IEC 60947-1:2020 IEC 60947-3:2020 AC ratings only |
Electrical data IEC | |
rated current (IEC): | 400 A |
rated voltage (IEC) AC: | 500 V |
rated isolation voltage Ui AC: | 1000 V |
rated surge voltage Uimp : | 12 kV |
Utilisation category AC (IEC 60947-3) : | AC-23B (500V) AC-22B (500V) AC-21B (500V) |
approved wth fuse links of operation class: | gG |
rated short-time withstand current Icw (1.0 s) max.: | 15 kA |
rated making capacity: | 30 kA |
power dissipation of the article:
The power dissipation at a typical load of 80 % results to 36.5 W.
(The power dissipation at full load would be 57.0 W.)
Mechanical lifespan (switching operations) 7000 rated short-circuit making capacity 30kA |
|
conv. therm. current in housing 400A, horizontal installation (adjacent poles) encapsulated 504 x 378 x 302mm 400A, vertical installation (poles beneath each other) encapsulated 500 x 500 x 300mm |
|
Shock protection at front with terminal space cover IP40 |
Mechanical data | |
W x H x D: | 270 x 237 x 197 |
weight: | 546.0 kg/100 |
poles: | 3-pole |
Mounting: | for mounting plate |
Type of fastening: screw-on
connection screw (clamps and wedge clamp terminal can be retrofitted),
screw connection
M10, 28Nm ± 10% torque,
clamp connection for lam. Cu
terminal space 18x1-10mm,
6-8Nm torque
wedge clamp connection, single
cross-section 70 - 150mm², s(r), f, f+AE** Cu - Al*, 6-8Nm torque
wedge clamp connection, double
cross-section 2 x 70 - 120mm², s(r), f, f+AE** Cu, 6-8Nm torque
* Aluminium conductors must be prepared before connection in accordance with the pertinent technical recommendations. The connections are to be checked at regular intervals and serviced not later than every 6 months.
** reduction in the max. conductor cross-sections may be required.
Terminal points | |
Not suitable for aluminium cables ! | |
screw M10 : |
Not suitable for aluminium cables ! | |
Reference |
When installing a cover, the switch-disconnector on the housing must not be closed, the safety instructions for the Emergency Stop switch must be observed. |
Find your contact
to the contact site
Wöhner GmbH & Co. KG
Elektrotechnische Systeme
Mönchrödener Str. 10
96472 Rödental
Order hotline (Germany)
+49 9563 751 161
order@woehner.de
Technical hotline (Germany)
+49 9563 751 260
support@woehner.com