Innovationen
产品
The picture may show a similar product.
订货号 32452000
EQUES®60Classic
母线转接器 25 A
适用于反向启动器 Eaton PKZM01, PKE12
90 x 200, 带导线 AWG 12 (4 mm²)
适用母线 12, 15, 20, 25, 30 x 5, 10 和异型母线
系统
60Classic
产品优势
导线末端超声铸压。
卡接机构用于在母线上滑动
产品组 | 05 |
分组 |
21 |
包装件数 | 2 |
EAN | 4021267324520 |
ECLASS 6.1 | 27370304 |
ECLASS 7.1 | 27370304 |
ETIM 4.0 | EC001531 |
ETIM 5.0 | EC001531 |
标准
IEC 61439-1:2020
UL 508
认证许可
CSA , UL , DNV GL
for UL feeder circuits >250V
型号: EEC6025-L
UL 文件: E123577, UL 类别 (适用美国) : NMTR https://www.ul.com
UL 文件: E123577, UL 类别 (适用加拿大) : NMTR7 https://www.ul.com
CSA 文件: 110285, CSA 等级: 3211-37 https://directories.csa-international.org
CCC 认证: 无需强制认证
Details IEC | |
标准 | |
IEC 61439-1:2020 |
Electrical data IEC | |
额定电流(IEC): | 25 A |
额定电压(IEC)AC: | 690 V |
rated isolation voltage Ui AC: | 800 V |
额定冲击耐受电压 Uimp: | 6 kV |
功率输出:
The power dissipation at a typical load of 80 % results to 1.2 W.
(The power dissipation at full load would be 1.9 W.)
Details UL | |
标准 | |
UL 508 |
for UL feeder circuits >250V |
Electrical data UL | |
额定电流 (UL): | 25 A |
额定电压 (UL) AC: | 600 V |
rated frequency (UL): | 50 / 60 Hz |
SCCR unprotected max.: | 5 kA |
3 cycles (without OPD) @ 600 V AC | |
SCCR protected max.: | 65 kA |
短路电流额定值: |
30 kA with PKZM0 12,5 A / 600 V AC
65 kA with PKZM0 16 A / 480 V AC 65 kA with PKZM0 25 A / 480 V AC 50 kA with PKZM0 32 A / 480 V AC |
机械数值 | |
宽 x 高 x 厚: | 90 x 200 x 63 |
重量: | 54.6 kg/100 |
极数: | 3线 |
适用母线: | 12, 15, 20, 25, 30 x 5, 10 和异型母线 |
连接端 | |
with leads | |
AWG10 (6 mm²) | |
wire stripping: | 9 mm |
There must be a clearance of at least 12 mm above the article to remove it from the busbar system. | |
短路稳定性: | 电机保护开关承载转接器的短路保护 |
for UL feeder circuits >250V |