Innovations
Service
产品
The picture may show a similar product.
订货号 03599000
NH 熔断器底座(母线式),400A
螺钉, 母线 5 - 10 mm
尺寸 2 / 单极
系统
100Energy
产品组 | 10 |
分组 |
33 |
包装件数 | 3 |
EAN | 4021267035990 |
ECLASS 6.1 | 27142106 |
ECLASS 7.1 | 27142106 |
ETIM 4.0 | EC000067 |
ETIM 5.0 | EC000067 |
标准
IEC 60269-1:2006 + A1:2009 + A2:2014
IEC 60269-2:2013 + A1:2016
for fuse links size: | NH 2 |
fuse links acc. to standard: | IEC / HD 60269-2 |
所使用熔断器的允许损耗功率: | 45 W |
Details IEC | |
标准 | |
IEC 60269-1:2006 + A1:2009 + A2:2014 IEC 60269-2:2013 + A1:2016 |
Electrical data IEC | |
额定电流(IEC): | 400 A |
额定电压(IEC)AC: | 690 V |
额定电压 (IEC) DC: | 440 V |
额定冲击耐受电压 Uimp: | 6 kV |
带熔断器时的分断能力: | 50 kA |
功率输出:
The power dissipation at a typical load of 80 % results to 12.0 W.
(The power dissipation at full load would be 18.7 W.)
Supplementary data IEC | |
下述参数已经在特定条件下通过测试得到验证。开始设计之前,请联系维纳尔咨询这些条件。 |
最大电压 IEC AC: | 800 V |
最大电压 IEC DC: | 800 V |
适用熔断器 IEC 60269-2 / DIN VDE 0636-201 尺寸2 损耗功率最高 45 W |
机械数值 | |
宽 x 高 x 厚: | 65 x 193 x 113 |
重量: | 75.8 kg/100 |
极数: | 1线 |
固定方式: 挂钩端子
连接螺钉:
螺钉连接 M10, 18 - 22 Nm 扭力矩
连接端 | |
Not suitable for aluminium cables ! |
Not suitable for aluminium cables ! | |
产品的绝缘性能与安装条件有关。 | |
所使用熔断器的允许损耗功率: | 45 W |
获取联系人
跳转至联系页面
电话:+86 10 67870300
邮箱:info@woehner.com.cn
网站:woehner.com.cn