Seleção de produtos

for UL feeder circuits >250V

módulo de conexão (01593)     PCF: 1,92 kg CO2e

A imagem pode mostrar um produto similar.

Descrição

Código da peça: 01593000A

CRITO®CrossBoard

módulo de conexão

com prensa-cabos 6 - 50 mm² / AWG 10 - AWG 1

3 polos

Sistema

CrossBoard® 125A / 250A, CrossBoard® 800 A

Vantagens do produto

direct connection to the CrossBoard, cover included

capable of feeding (up to 125 A) 1 or 2 CrossBoards simultaneously with balanced or unbalanced load on the boards.

can be used without cables as a bridge connection between 2 CrossBoards up to 125 A. Feeding a third CrossBoard with cables is acceptable, but the total current cannot exceed 125 A.

touch-safe

CRITO® unlockable from top or bottom

Grupo de produto 07
Subgroup 42
Unidade por pacote 1
EAN 4021267015930
ECLASS 6.1 27141146
ECLASS 7.1 27141146
ETIM 4.0 EC000001
ETIM 5.0 EC000001

Aprovações

Standards

IEC 61439-1:2020
IEC 60999-1:1999
IEC 60999-2:2003

UL 508

Approvals

UL

for UL feeder circuits >250V

Número de tipo: CR45-A

UL file: E123577, UL category (for USA): NMTR https://www.ul.com

UL file: E123577, UL category (for Canada): NMTR7 https://www.ul.com

Aprovação CCC: no certification required

Dados técnicos

Dados IEC
Standards
IEC 61439-1:2020
IEC 60999-1:1999
IEC 60999-2:2003
Dados elétricos IEC
Corrente de medição (IEC): 125 A
Tensão de medição (IEC) AC: 690 V
Tensão nominal de isolamento: 800 V
rated peak withstand current  Ipk max.: 15 kA
Dados adicionais IEC

The following values have been verified with tests under certain conditions. Please ask Wöhner for this conditions before designing your panel.

tensão máxima IEC AC: 800 V
tensão máxima IEC DC: 800 V
current capacity (IEC) max.: 125 A
Dados UL
Standards
UL 508
for UL feeder circuits >250V
suitable for field-installed conductors
Dados electricos UL
corrente nominal (UL): 100 A
rated voltage (UL) AC: 600 V
rated frequency (UL): 50 / 60 Hz
SCCR unprotected max.: 10 kA
3 cycles (without OPD) @ 600 V AC
SCCR protected max.: 100 kA
SCCR: 65 kA with any DIVQ/7 circuit breaker 100 A / 600 V AC
100 kA with any DIVQ/7 circuit breaker 100 A / 480 V AC
100 kA with JDDZ fuse Class J 175 A / 600 V AC
Dados mecânicos
L x A x P: 45 x 160 x 92
Peso: 25,0 kg/100
Polaridade: 3 polos
front degree of protection: IP20
pontos terminais
cage clamp connection
screw drive: S4
wire stripping: 17 mm
min. cross-section: 6 mm²
max. cross-section: 50 mm²
Md min.: 5,0 Nm
Md max.: 6,0 Nm
  
min. cross-section UL: AWG 10
max. cross-section UL: AWG 1/0
torque (UL): 44 - 53 lb-in
  

6 - 50 mm² / AWG 10 - AWG 1
feindrähtig, direkt geklemmt oder mit Aderendhülse,
6 - 35 mm² Rundleiter mehrdrähtig,

(feindrähtig mit Aderendhülse eventuell nicht mit maximalen Querschnitt möglich)

Instruções de Aplicação

The insulation performance of the article depends on the installation conditions.
for UL feeder circuits >250V

Links

Downloads

Acessórios

01604000A
tampa de proteção IP20 contra toque
for connection module 01593
Mais