Selezione prodotto

for UL feeder circuits >250V

Base per fusibili cilindr. (33308)

The picture may show a similar product.

Descrizione

Cod.art.: 33308000

QUADRON®Panel

Base per fusibili cilindr.

Class J / 3P, morsetti 300 mm²

400 A / 600 V (54x181)

für Montageplatte

Montaggio

Mounting plate

gruppo di prodotto 16
sottogruppo prodotto 15
Pz / conf. 1
EAN 4021267333089
pagina catalogo 2020 : 6.10
ECLASS 6.1 27142190
ECLASS 7.1 27142190
ETIM 4.0 EC002705
ETIM 5.0 EC002705

Certificazioni

Norme

IEC 60269-1:2006 + A1:2009 + A2:2014
IEC 60269-2:2013 + A1:2016, Fuse system H

UL 4248-8

UL 4248-1

Omologazioni

CSA , UL , EAC

for UL feeder circuits >250V

type no.: JC400

EAC Type: AJC

UL file: E230163, UL category (for USA): IZLT https://www.ul.com

UL file: E230163, UL category (for Canada): IZLT7 https://www.ul.com

CSA file: 110285, CSA class: 3211-37 https://directories.csa-international.org

Dati tecnici

per fusibili di grandezza: Class J 400 A
fusibile secondo norma: UL 248-8
potenza diss. max. ammissibile del fusibile inserito: 38 W
Details IEC
Norme
IEC 60269-1:2006 + A1:2009 + A2:2014
IEC 60269-2:2013 + A1:2016, Fuse system H

Valori elettrici

power dissipation of the article:

The power dissipation at a typical load of 80 % results to 9,5 W.

(The power dissipation at full load would be 14,8 W.)

for Class J fuses 225 - 400A as per UL 248-8 (54x181)
Details UL
Norme
UL 4248-8
UL 4248-1
for UL feeder circuits >250V
suitable for field-installed conductors
Electrical data UL
corrente nominale (UL): 400 A
tensione nominale (UL) AC: 600 V
frequenza nominale (UL): 50 / 60 Hz
tensione nominale (UL) DC: 600 V
for wires UL: Cu 75°C
SCCR: 200 kA
Valori meccanici
L x A x P: 256 x 267 x 133
peso: 672,0 kg/100
Poli: 3 poli
Mounting: für Montageplatte
Connessioni
Not suitable for aluminium cables !
  
min. cross-section UL: AWG 4
max. cross-section UL: MCM 600
for wires UL: Cu 75°C
  

tunnel terminal with hole of 23,0 mm diameter

acc. to IEC / EN :
16 - 240 (300) mm²
flexible cables, directly or with wire-end ferrule,
solid and stranded round cables,
Md 38 - 40 Nm

(flexible cables of maximum cross-section may not fit when using wire-end ferrule)

acc. to UL :
AWG 4 - MCM 600
stranded cables Class B acc. to UL 486E
336 - 355 lb.in.

Avvisi e consigli

Shock protection through push-on covers.

Links

Downloads

Accessori

03224000A
Fusibile 250 A
-Mersen-
600 V AC, fast acting
Class J, 54x181
Di Più

03225000A
Fusibile 300 A
-Mersen-
600 V AC, fast acting
Class J, 54x181
Di Più

03226000A
Fusibile 350 A
-Mersen-
600 V AC, fast acting
Class J, 54x181
Di Più

03227000A
Fusibile 400 A
-Mersen-
600 V AC, fast acting
Class J, 54x181
Di Più

03238000
Fusibile 250 A
-Mersen-
600 V AC, time delay
Class J, 54x181
Di Più

03239000
Fusibile 300 A
-Mersen-
600 V AC, time delay
Class J, 54x181
Di Più

03240000
Fusibile 350 A
-Mersen-
600 V AC, time delay
Class J, 54x181
Di Più

03241000
Fusibile 400 A
-Mersen-
600 V AC, time delay
Class J, 54x181
Di Più

Similar products

33311000
QUADRON®60Classic
Base per fusibili cilindr. Class J, connessione in basso / alto
per fusibili Class J, 225 - 400 A (54x181)
3p, con morsetto a gabbia
connessione cavi in alto o basso
per barre: 30 x 10 e barre profilate
Di Più

Trova il tuo contatto

to the contact site

Wöhner GmbH & Co. KG
Elektrotechnische Systeme
Mönchrödener Str. 10
96472 Rödental

Order hotline (Germany)
+49 9563 751 161
order@woehner.de

Technical hotline (Germany)
+49 9563 751 260
support@woehner.com