Innovazioni
Prodotti
The picture may show a similar product.
Cod.art.: 31300000
AMBUS®Panel
Base sezion. per fusibili cilindr., con LED
Class CC / 3P
30 A / 600 V
indication of a released fuse link
for mounting rail
Montaggio
Panel
Vantaggi prodotto
large clamping range, also for two identical conductors (adjacent)
holder for label
with indicator for tripped fuse
any polarity for DC voltage
gruppo di prodotto | 17 |
sottogruppo prodotto | 07 |
pz/ conf. | 4 |
EAN | 4021267313005 |
ECLASS 6.1 | 27142190 |
ECLASS 7.1 | 27142190 |
ETIM 4.0 | EC002705 |
ETIM 5.0 | EC002705 |
Norme
IEC 60269-1:2006 + A1:2009 + A2:2014
IEC 60269-2:2013 + A1:2016, Fuse system J
UL 4248-1
UL 4248-4
Omologazioni
CSA , UL , CCC
for UL feeder circuits >250V
type no.: AESCC
UL file: E230163, UL category (for USA): IZLT https://www.ul.com
UL file: E230163, UL category (for Canada): IZLT7 https://www.ul.com
CSA file: 110285, CSA class: 6225-01 https://directories.csa-international.org
CCC certificate: 21107299296
per fusibili di grandezza: | Class CC |
fusibile secondo norma: | UL 248-4 |
potenza diss. max. ammissibile del fusibile inserito: | 4 W |
Details IEC | |
Norme | |
IEC 60269-1:2006 + A1:2009 + A2:2014 IEC 60269-2:2013 + A1:2016, Fuse system J |
Electrical data IEC | |
tensione min. di impiego AC: | 110 V |
tensione min. di impiego DC: | 110 V |
power dissipation of the article:
The power dissipation at a typical load of 80 % results to 0,6 W.
(The power dissipation at full load would be 0,9 W.)
indicator light operating voltage range: 110 - 600 V AC / DC |
Details UL | |
Norme | |
UL 4248-1
UL 4248-4 |
for UL feeder circuits >250V | |
suitable for field-installed conductors |
Electrical data UL | |
corrente nominale (UL): | 30 A |
tensione nominale (UL) AC: | 600 V |
tensione min. di impiego AC: | 110 V |
frequenza nominale (UL): | 50 / 60 Hz |
tensione nominale (UL) DC: | 600 V |
tensione min. di impiego DC: | 110 V |
SCCR: | 200 kA |
Valori meccanici | |
L x A x P: | 54 x 81 x 58 |
peso: | 18,5 kg/100 |
Poli: | 3 poli |
Mounting: | for mounting rail |
grado di protezione: | IP20 |
grado di protezione dal fronte: | IP20 |
Connessioni | |
cage clamp connection | |
screw drive: | PZ2 |
wire stripping: | 11 mm |
min. cross-section: | 0,75 mm² |
max. cross-section: | 25 mm² |
Md min.: | 2,0 Nm |
Md max.: | 2,5 Nm |
Not suitable for aluminium cables ! | |
min. cross-section UL: | AWG 18 |
max. cross-section UL: | AWG 4 |
for applications acc. to IEC / EN : |
Not suitable for aluminium cables ! | |
Avvisi e consigli |
The indicator light signals that the fuse has tripped, but only when the closed fuse-holder is under voltage. |
potenza diss. max. ammissibile del fusibile inserito: | 4 W |
for UL feeder circuits >250V |
Trova il tuo contatto
to the contact site
Wöhner GmbH & Co. KG
Elektrotechnische Systeme
Mönchrödener Str. 10
96472 Rödental
Order hotline (Germany)
+49 9563 751 161
order@woehner.de
Technical hotline (Germany)
+49 9563 751 260
support@woehner.com