Cod.art.: 32724000A
EQUES®185Power
Adattatore 1320 A
300 x 652, coll.al sistema in basso, mont.su barre forate, fasi invertite
per ABB Tmax T7, XT7 (1600 A), Emax E1.2 (1600 A), Siemens 3VA27 (1600 A)
per barre 30, 40, 60, 80, 100, 120 x 10
not suitable for systems with CrossLink protection modules
Montaggio
185Power
gruppo di prodotto | 05 |
sottogruppo prodotto | 48 |
pz/ conf. | 1 |
EAN | 4021267327248 |
ECLASS 6.1 | 27370304 |
ECLASS 7.1 | 27370304 |
ETIM 4.0 | EC001531 |
ETIM 5.0 | EC001531 |
Norme
IEC 61439-1:2020
UL 508
Omologazioni
UL
for UL feeder circuits >250V
type no.: EQ185-A1600-S
UL file: E123577, UL category (for USA): NMTR https://www.ul.com
UL file: E123577, UL category (for Canada): NMTR7 https://www.ul.com
Omologazione CCC : no certification required
Details IEC | |
Norme | |
IEC 61439-1:2020 |
Electrical data IEC | |
corrente nominale (IEC): | 1320 A |
tensione nominale (IEC) AC: | 690 V |
tensione nominale (IEC) DC: | 800 V |
tensione nominale di isolamento Ui AC: | 1000 V |
tensione nominale di isolamento Ui DC: | 1000 V |
tensione di picco Uimp: | 12 kV |
resistenza nom. alla corrente di picco Ipk max.: | 106 kA |
corrente nom. di breve durata Icw (1,0 s) max.: | 50 kA |
power dissipation of the article:
The power dissipation at a typical load of 80 % results to 237,4 W.
(The power dissipation at full load would be 371,0 W.)
Details UL | |
Norme | |
UL 508 |
for UL feeder circuits >250V |
Electrical data UL | |
corrente nominale (UL): | 1200 A |
tensione nominale (UL) AC: | 1000 V |
frequenza nominale (UL): | 50 / 60 Hz |
SCCR unprotected max.: | 50 kA |
3 cycles (without OPD) @ 1000 V AC |
Valori meccanici | |
L x A x P: | 300 x 652 x 85 |
peso: | 3140,0 kg/100 |
Poli: | 3 poli |
per barre: | 30, 40, 60, 80, 100, 120 x 10 |
CT can be integrated in the device: | ja |
Avvisi e consigli |
Ausreichend Platz für 2x3 Stromwandler vorhanden. |
short-circuit withstandability: | the short-circuit capacity of the combination of adapter and MCCB depends on the MCCB |