Adattatore EEC 32 A (32442)

The picture may show a similar product.

Descrizione

Cod.art.: 32442000

EQUES®60Classic

Adattatore EEC 32 A

con 2 guide DIN scorrevoli

54 x 200, con cavi AWG 10 (6 mm²)

per barre 12, 15, 20, 25, 30 x 5, 10 e barre profilate

Montaggio

60Classic

Vantaggi prodotto

Conductor ends ultrasonically sealed.
Click mechanism when pushing onto the busbar.

gruppo di prodotto 05
sottogruppo prodotto 21
pz/ conf. 4
EAN 4021267324421
ECLASS 6.1 27370304
ECLASS 7.1 27370304
ETIM 4.0 EC001531
ETIM 5.0 EC001531

Certificazioni

Norme

IEC 61439-1:2020

UL 508

Omologazioni

CSA , UL , DNV GL

for UL feeder circuits >250V

type no.: EEC6032-L

UL file: E123577, UL category (for USA): NMTR https://www.ul.com

UL file: E123577, UL category (for Canada): NMTR7 https://www.ul.com

CSA file: 110285, CSA class: 3211-37 https://directories.csa-international.org

Omologazione CCC : no certification required

Dati tecnici

Details IEC
Norme
IEC 61439-1:2020
Electrical data IEC
corrente nominale (IEC): 32 A
tensione nominale (IEC) AC: 690 V
tensione nominale di isolamento Ui AC: 800 V
tensione di picco Uimp: 6 kV

power dissipation of the article:

The power dissipation at a typical load of 80 % results to 1,5 W.

(The power dissipation at full load would be 2,4 W.)

Details UL
Norme
UL 508
for UL feeder circuits >250V
Electrical data UL
corrente nominale (UL): 30 A
tensione nominale (UL) AC: 600 V
frequenza nominale (UL): 50 / 60 Hz
SCCR unprotected max.: 5 kA
3 cycles (without OPD) @ 600 V AC
SCCR protected max.: 65 kA
SCCR: 65 kA with any DIVQ/7 circuit breaker 40 A / 480 V AC
65 kA with any NKJH/7 Comb. Motor Controller type E 32 A / 480 V AC
Valori meccanici
L x A x P: 54 x 200 x 63
peso: 38,0 kg/100
Poli: 3 poli
per barre: 12, 15, 20, 25, 30 x 5, 10 e barre profilate
Connessioni
with leads
AWG10 (6 mm²)
wire stripping: 9 mm

Application notes

There must be a clearance of at least 12 mm above the article to remove it from the busbar system.

Avvisi e consigli

For compact mounting of complete motor circuits with commercially available switchgear and safe mechanical and electrical connection to the busbar system.

short-circuit withstandability: the short-circuit capacity of the combination of adapter and motor starter depends on the motor starter
for UL feeder circuits >250V

Links

Downloads

Accessori

32969000
bloccaggio laterale per guide DIN
Di Più

32963000
Modulo laterale per adattatori EEC
per entrambi lati
9 x 200
per: EEC60..
Di Più

32953000A
slitta di posizionamento per Siemens S2
NUOVO
Di Più

Trova il tuo contatto

to the contact site

Wöhner GmbH & Co. KG
Elektrotechnische Systeme
Mönchrödener Str. 10
96472 Rödental

Order hotline (Germany)
+49 9563 751 161
order@woehner.de

Technical hotline (Germany)
+49 9563 751 260
support@woehner.com