sectionneur à fusible NH taille 3, 630 A, à encastrer (33151)

The picture may show a similar product.

Description

Référence 33151 000

QUADRON®Panel

sectionneur à fusible NH taille 3, 630 A, à encastrer

vis M12

with electromechanical fuse monitoring

for mounting plate

Système

Panel

Avantages produit

Disconnectors are equipped with arc chambers.
The shock protection is split into 2 for safe connection of the conductors.

Groupe de produits 09
Sous-groupe 13
Dimensions de l'emballage 1
EAN 4021267331511
ECLASS 6.1 27142108
ECLASS 7.1 27142108
ETIM 4.0 EC001040
ETIM 5.0 EC001040

Homologations

Normes

IEC 60947-1:2020
IEC 60947-3:2020 AC ratings only

UL 4248-1

Approbations

IEC (CB) , UL , CCC , DNV GL

for UL feeder circuits >250V

Type: LTS-3

UL file: E230163, UL category (for USA): IZLT2 https://www.ul.com

CCC certificate: 2004010302117263

Données techniques

for fuse links size: NH 3
fuse links acc. to standard: IEC / HD 60269-2
live grip lugs required: Oui
permitted power dissipation of the fuse-link: 48 W
requirements for contact parts: Fuse links with silver-plated contact pieces recommended.
For fuse links with nickel-plated contact pieces, a reduction factor of 0.8 is to be observed.
Details IEC
Normes
IEC 60947-1:2020
IEC 60947-3:2020 AC ratings only
Electrical data IEC
Courant assigné (IEC): 630 A
Tension assignée (IEC) CA: 690 V
Tension assignée (IEC) CC: 250 V
rated isolation voltage Ui AC: 800 V
rated isolation voltage Ui DC: 250 V
Tension assignée de tenue aux chocs Uimp: 6 kV
Catégorie d'emploi CA: AC-23B (400 V)
AC-22B (690 V)
AC-21B (690 V)
Catégorie d'emploi CC: DC specifications: 2 current paths (L1,L3) in series
DC-22B (250V)
cond. short-circuit current with fuses (AC): 50 kA / 690 V
approved wth fuse links of operation class: gG

power dissipation of the article:

The power dissipation at a typical load of 80 % results to 23,0 W.

(The power dissipation at full load would be 36,0 W.)

Supplementary data IEC

Les valeurs suivantes ont été vérifiées par des tests sous certaines conditions. Veuillez demander ces conditions à Wöhner avant de concevoir votre armoire.

Tension maximale IEC CA: 725 V
Tension maximale IEC CC: 262 V
Les unités de commutation à fusibles conformes à la norme IEC 60947-3 ne peuvent fonctionner au-delà de la tension de service nominale que si elles sont utilisées comme sectionneurs à fusible sans fonction de commutation de charge et cela jusqu'à la tension d'isolement assignée et sont marquées en conséquence.
for fuse links IEC 60269-2-1 (I) / DIN VDE 0636-201 size 3 up to 48W power dissipation, with grip lugs under voltage
Entsprechend den angegeben AC- und DC- Schalteigenschaften und unter Berücksichtigung der Überlastbedingungen, sind gewisse Abstände zu geerdeten Metallteilen einzuhalten. Nähere Informationen auf Anfrage.
Bei Verwendung als Trennschalter ist die Einhaltung der Abstände nicht erforderlich.
Degree of protection IP30 at front, degree of protection near terminal depends on installation

fuse monitoring:
AC24 - 690V, DC24 - 250V, 100kA,
auxiliary energy not required,
potential-free opener and closer
Details UL
Normes
UL 4248-1
for UL feeder circuits >250V
Electrical data UL
rated current (UL): 600 A
rated voltage (UL) AC: 600 V
rated frequency (UL): 50 / 60 Hz
Icc: 100 kA
Charactéristiques mécaniques
L x H x P: 256 x 300 x 218
Poids: 556,0 kg/100
Pôles: 3 pôles
Mounting: for mounting plate
front degree of protection: IP30
Points de raccordement
screw connection
M12
screw drive: SW18
Md min.: 35,0 Nm
Md max.: 40,0 Nm
Not suitable for aluminium cables !

Application notes

Not suitable for aluminium cables !
Les unités de commutation à fusibles conformes à la norme IEC 60947-3 ne peuvent fonctionner au-delà de la tension de service nominale que si elles sont utilisées comme sectionneurs à fusible sans fonction de commutation de charge et cela jusqu'à la tension d'isolement assignée et sont marquées en conséquence.
live grip lugs required: Oui
permitted power dissipation of the fuse-link: 48 W
requirements for contact parts: Fuse links with silver-plated contact pieces recommended.
For fuse links with nickel-plated contact pieces, a reduction factor of 0.8 is to be observed.
for UL feeder circuits >250V

Links

Documentation

Accessoires

connection accessories

33147 000
borne prisme, double, pour câbles Cu
2x 150 mm²
taille 3
Plus

33165 000
borne à étrier pour câbles Cu
150 - 300 mm²
pour: QCB-NH2, LTS-F 400, LTS 630
Plus

33168 000
borne prisme, simple, pour câbles Cu et Al
150 - 300 mm²
taille 3
Plus

33385 000
borne prisme, double, pour câbles Cu
2x 185 mm²
taille 3
Plus

33272 000
extension pour 2 cosses
taille 3
Plus

covers

33144 000
cache pour cosses, raccordement en haut et en bas
pour QCB-NH3
pour: QCB-NH3
Plus

33153 000
cadre, simple
248 x 330
taille 2
Plus

33154 000
cadre, simple
290 x 330
taille 3
Plus

33155 000
protection contre le contact
pour sectionneur à fusible NH taille 1-3
pour la fermeture de la zone de la poignée par l'arrière
Plus

33419 000
cache bornes
pour interrupteur sectionneur à fusibles NH, taille 3, max. 600 A
Plus

further accessories

33156 000
contact de signalisation
commutateur 250 V AC / 5 A, 30 V DC / 4 A
Plus

33157 000
verrouillage du couvercle
pour fil de plombage ou 3 cadenas avec manille de 4 - 7 mm
Taille 1 - 3
Plus

Similar products

33332 000
QUADRON®Panel
sectionneur à fusible NH taille 3, 630 A, à encastrer
vis M12
with electronic fuse monitoring
for mounting plate
Plus

Trouver votre contact

to the contact site

Wöhner GmbH & Co. KG
Elektrotechnische Systeme
Mönchrödener Str. 10
96472 Rödental

Order hotline (Germany)
+49 9563 751 161
order@woehner.de

Technical hotline (Germany)
+49 9563 751 260
support@woehner.com