            Innovaciones
            
        
        
      
        
            Productos
            
        
      	
        
        
        
    for UL feeder circuits >250V
La imagen puede mostrar un producto similar.
Part No.: 01068 000
CRITO®
borne universal de conexión de cable
16 - 120 mm², AWG 6 - 250 MCM
para barras barras planas de 5 mm de espesor
sistema
60Classic, 30Compact 3P
ventajas del producto
Terminal with integrated holding spring, captive clamping screw and opened terminal space.
Indication of nominal cross-section and tightening torque noted on the terminal.
| grupo de producto | 07 | 
| subgrupo | 18 | 
| embalaje | 25 | 
| EAN | 4021267010683 | 
| ECLASS 6.1 | 27141146 | 
| ECLASS 7.1 | 27141146 | 
| ETIM 4.0 | EC000001 | 
| ETIM 5.0 | EC000001 | 
Normas
IEC 61439-1:2020
IEC 60999-1:1999
IEC 60999-2:2003
UL 508
homologaciónes
CSA , UL
																		 
																		 
tipo: 524
UL file: E123577, UL category (for USA): NMTR2 https://www.ul.com
UL file: E123577, UL category (for Canada): NMTR8 https://www.ul.com
CSA file: 110285, CSA class: 3211-37 https://directories.csa-international.org
Homologación CCC: no es obligatoria la certificación
| datos IEC | |
| Normas | |
| IEC 61439-1:2020 IEC 60999-1:1999 IEC 60999-2:2003 | 
| datos electricos IEC | |
| intensidad de corriente nominal (IEC): | 250 A | 
| tensión nominal (IEC) AC: | 690 V | 
| resistencia a corriente de pico Ipk máx. : | 27.7 kA | 
disipación de potencia del articulo:
The power dissipation at a typical load of 80 % results to 0,0 W.
(The power dissipation at full load would be 0,0 W.)
| datos adicionales IEC | |
| Los siguientes valores han sido verificados con los test bajo ciertas condiciones. Por favor, pregunte a Wöhner por estas condiciones antes de diseñar su cuadro. | 
| tensión máxima (IEC) AC: | 1000 V | 
| tensión máxima (IEC) DC: | 1500 V | 
| máxima intensidad de corriente (IEC): | 440 A | 
| datos UL | |
| Normas | |
| UL 508 | 
| suitable for field-installed conductors | 
| datos electricos UL | |
| intensidad de corriente nominal (UL): | 255 A | 
| tensión nominal (UL) AC: | 600 V | 
| frecuencia nominal (UL): | 50 / 60 Hz | 
| SCCR: | 18 kA | 
| datos mecánicos | |
| An x A x P: | 24 x 36 x 55 | 
| peso: | 10,6 kg/100 | 
| para barras: | barras planas de 5 mm de espesor | 
| puntos de apriete | |
| screw clamp connection | |
| screw drive: | SW17 | 
| min. cross-section: | 16 mm² | 
| max. cross-section: | 120 mm² | 
| rm: | 16 - 120 mm² | 
| f: | 16 - 120 mm² | 
| f + AE: | 16 - 120 mm² | 
| (f + AE may not fit with max. cross-section) | |
| Md min.: | 12,0 Nm | 
| Md max.: | 18,0 Nm | 
| Not suitable for aluminium cables ! | |
| Espacio de apriete: | 17 x 15 | 
| lam. Cu width: | 13 - 16 mm | 
| lam. Cu thickness: | 3 - 10 mm | 
| number of lam. Cu: | 1 | 
| min. cross-section UL: | AWG 6 | 
| max. cross-section UL: | MCM 250 | 
| Not suitable for aluminium cables ! | |
| La capacidad de aislamiento del artículo depende de las condiciones de la instalación. | |
| La posible utilización para "feeder circuits" (respecto de los "feeder spacings" como requerimiento) depende de las condiciones de la instalación. | 
 
						
                01413
        000
        
        
            tapa, 3 polos
            
            
            84 mm de anchura
            84 x 200 x 55
            
            para barras: 12, 15, 20, 25, 30 x 5, 10 y barras perfiladas 
            
        Mas
        
						
Busca tu contacto
a la pagina de contactos
Wöhner GmbH & Co. KG
Elektrotechnische Systeme
Mönchrödener Str. 10
96472 Rödental
Order hotline (Germany)
+49 9563 751 161
order@woehner.de
Technical hotline (Germany)
+49 9563 751 260
support@woehner.com