adaptador para embarrado de 32 A (32446)

La imagen puede mostrar un producto similar.

Descripción

Part No.: 32446000

EQUES®60Classic

adaptador para embarrado de 32 A

2 carriles de montaje ajustables

81 x 200, con cables 10 AWG (6 mm²)

para barras 12, 15, 20, 25, 30 x 5, 10 y barras perfiladas

sistema

60Classic

ventajas del producto

Conductor ends ultrasonically sealed.
Click mechanism when pushing onto the busbar.

grupo de producto 05
subgrupo 21
embalaje 4
EAN 4021267324469
ECLASS 6.1 27370304
ECLASS 7.1 27370304
ETIM 4.0 EC001531
ETIM 5.0 EC001531

Homologaciónes

Normas

IEC 61439-1:2020

UL 508

homologaciónes

CSA , UL , DNV GL

for UL feeder circuits >250V

tipo: EEC6032-L

UL file: E123577, UL category (for USA): NMTR https://www.ul.com

UL file: E123577, UL category (for Canada): NMTR7 https://www.ul.com

CSA file: 110285, CSA class: 3211-37 https://directories.csa-international.org

Homologación CCC: no es obligatoria la certificación

Datos técnicos

datos IEC
Normas
IEC 61439-1:2020
datos electricos IEC
intensidad de corriente nominal (IEC): 32 A
tensión nominal (IEC) AC: 690 V
tensión nominal de aislamiento Ui AC: 800 V
tensión de pico Uimp: 6 kV

disipación de potencia del articulo:

The power dissipation at a typical load of 80 % results to 1.5 W.

(The power dissipation at full load would be 2.4 W.)

datos UL
Normas
UL 508
for UL feeder circuits >250V
datos electricos UL
intensidad de corriente nominal (UL): 30 A
tensión nominal (UL) AC: 600 V
frecuencia nominal (UL): 50 / 60 Hz
SCCR unprotected max.: 5 kA
3 cycles (without OPD) @ 600 V AC
SCCR protected max.: 100 kA
SCCR: 65 kA with any NKJH/7 Comb. Motor Controller type E 32 A / 480 V AC
100 kA with JDDZ fuse Class CC, CF, J or T 60 A / 600 V AC
65 kA with any DIVQ/7 circuit breaker 40 A / 480 V AC
datos mecánicos
An x A x P: 81 x 200 x 63
peso: 49.5 kg/100
Polaridad: 3 polos
para barras: 12, 15, 20, 25, 30 x 5, 10 y barras perfiladas
puntos de apriete
with leads
AWG10 (6 mm²)
wire stripping: 9 mm

Application notes

There must be a clearance of at least 12 mm above the article to remove it from the busbar system.

Notas

For compact mounting of complete motor circuits with commercially available switchgear and safe mechanical and electrical connection to the busbar system.

short-circuit withstandability: the short-circuit capacity of the combination of adapter and motor starter depends on the motor starter
for UL feeder circuits >250V

Links

Downloads

Accesorios

32963000
módulo lateral para adaptadores para embarrado
acoplable en ambos lados
9 x 200
para: EEC60..
Mas

Busca tu contacto

a la pagina de contactos

Wöhner GmbH & Co. KG
Elektrotechnische Systeme
Mönchrödener Str. 10
96472 Rödental

Order hotline (Germany)
+49 9563 751 161
order@woehner.de

Technical hotline (Germany)
+49 9563 751 260
support@woehner.com