Company
Innovations
Products
for UL feeder circuits >250V
The picture may show a similar product.
Part No.: 33307 000
QUADRON®Panel
holder for cylindrical fuses
Class J / 3P, terminal 150 mm²
200 A / 600 V (41x146)
for mounting plate
System
Panel
Product group | 16 |
Subgroup | 12 |
pack size | 1 |
EAN | 4021267333072 |
ECLASS 6.1 | 27142190 |
ECLASS 7.1 | 27142190 |
ETIM 4.0 | EC002705 |
ETIM 5.0 | EC002705 |
Standards
IEC 60269-1:2006 + A1:2009 + A2:2014
IEC 60269-2:2013 + A1:2016, Fuse system H
UL 4248-8
UL 4248-1
Approvals
CSA , UL
for UL feeder circuits >250V
type number: JC200
UL file: E230163, UL category (for USA): IZLT https://www.ul.com
UL file: E230163, UL category (for Canada): IZLT7 https://www.ul.com
CSA file: 110285, CSA class: 3211-37 https://directories.csa-international.org
for fuse links size: | Class J 200 A |
fuse links acc. to standard: | UL 248-8 |
permitted power dissipation of the fuse-link: | 22 W |
Details IEC | |
Standards | |
IEC 60269-1:2006 + A1:2009 + A2:2014 IEC 60269-2:2013 + A1:2016, Fuse system H |
Electrical data
power dissipation of the article:
The power dissipation at a typical load of 80 % results to 4.7 W.
(The power dissipation at full load would be 7.4 W.)
for Class J fuses 110 - 200A as per UL 248-8 (41x146) |
Details UL | |
Standards | |
UL 4248-8
UL 4248-1 |
for UL feeder circuits >250V | |
suitable for field-installed conductors |
Electrical data UL | |
rated current (UL): | 200 A |
rated voltage (UL) AC: | 600 V |
rated frequency (UL): | 50 / 60 Hz |
rated voltage (UL) DC: | 600 V |
for wires UL: | Cu 75°C |
SCCR: | 200 kA |
Mechanical data | |
W x H x D: | 210 x 255 x 117 |
weight: | 405.0 kg/100 |
poles: | 3-pole |
Mounting: | for mounting plate |
Terminal points | |
re: | 10 - 150 mm² |
rm: | 10 - 150 mm² |
f: | 10 - 150 mm² |
f + AE: | 10 - 150 mm² |
(f + AE may not fit with max. cross-section) | |
Md min.: | 16.0 Nm |
Md max.: | 18.0 Nm |
Not suitable for aluminium cables ! | |
for wires UL: | Cu 75°C |
tunnel terminal with hole of 17,0 mm diameter |
Not suitable for aluminium cables ! | |
Shock protection through push-on covers. |
|
permitted power dissipation of the fuse-link: | 22 W |
for UL feeder circuits >250V |
03219
000A
fuse link 125 A
-Mersen-
600 V AC, fast acting
Class J, 200 A frame
More
03220
000A
fuse link 150 A
-Mersen-
600 V AC, fast acting
Class J, 200 A frame
More
03221
000
fuse link 175 A
-Mersen-
600 V AC, fast acting
Class J, 200 A frame
More
03222
000
fuse link 200 A
-Mersen-
600 V AC, fast acting
Class J, 200 A frame
More
03233
000
fuse link 125 A
-Mersen-
600 V AC, time delay
Class J, 200 A frame
More
03234
000
fuse link 150 A
-Mersen-
600 V AC, time delay
Class J, 200 A frame
More
03235
000
fuse link 175 A
-Mersen-
600 V AC, time delay
Class J, 200 A frame
More
03236
000
fuse link 200 A
-Mersen-
600 V AC, time delay
Class J, 200 A frame
More
Find your contact
to the contact site
Wöhner GmbH & Co. KG
Elektrotechnische Systeme
Mönchrödener Str. 10
96472 Rödental
Order hotline (Germany)
+49 9563 751 161
order@woehner.de
Technical hotline (Germany)
+49 9563 751 260
support@woehner.com