Select product

for UL feeder circuits >250V

holder for cylindrical fuses (33307)

The picture may show a similar product.

Description

Part No.: 33307000

QUADRON®Panel

holder for cylindrical fuses

Class J / 3P, terminal 150 mm²

200 A / 600 V (41x146)

System

Mounting plate

Product group 16
Subgroup 12
pack size 1
EAN 4021267333072
catalog page 2010 : 5.10
ECLASS 6.1 27142190
ECLASS 7.1 27142190
ETIM 4.0 EC002705
ETIM 5.0 EC002705

Approvals

Standards

IEC 60269-1:2006 + A1:2009 + A2:2014
IEC 60269-2:2013 + A1:2016, Fuse system H

UL 4248-8

UL 4248-1

Approvals

CSA , UL , EAC

for UL feeder circuits >250V

type number: JC200

EAC Type: AJC

UL file: E230163, UL category (for USA): IZLT https://www.ul.com

UL file: E230163, UL category (for Canada): IZLT7 https://www.ul.com

CSA file: 110285, CSA class: 3211-37 https://directories.csa-international.org

Technical data

for fuse links size: Class J 200 A
fuse links acc. to standard: UL 248-8
permitted power dissipation of the fuse-link: 22 W
Details IEC
Standards
IEC 60269-1:2006 + A1:2009 + A2:2014
IEC 60269-2:2013 + A1:2016, Fuse system H

Electrical data

power dissipation of the article:

The power dissipation at a typical load of 80 % results to 4.7 W.

(The power dissipation at full load would be 7.4 W.)

for Class J fuses 110 - 200A as per UL 248-8 (41x146)
Details UL
Standards
UL 4248-8
UL 4248-1
for UL feeder circuits >250V
suitable for field-installed conductors
Electrical data UL
rated current (UL): 200 A
rated voltage (UL) AC: 600 V
rated frequency (UL): 50 / 60 Hz
rated voltage (UL) DC: 600 V
for wires UL: Cu 75°C
SCCR: 200 kA
Mechanical data
W x H x D: 210 x 255 x 117
weight: 405.0 kg/100
poles: 3-pole
Terminal points
Not suitable for aluminium cables !
for wires UL: Cu 75°C
  

tunnel terminal with hole of 17,0 mm diameter

acc. to IEC / EN :
10 - 150 mm²
flexible cables, directly or with wire-end ferrule,
solid and stranded round cables,
Md 16 - 18 Nm

(flexible cables of maximum cross-section may not fit when using wire-end ferrule)

acc. to UL :
AWG 8 - MCM 300
stranded cables Class B acc. to UL 486E
142 - 160 lb.in.

Reference

Shock protection through push-on covers.

Links

Downloads

Accessories

03219000A
fuse link 125 A
-Mersen-
600 V AC, fast acting
Class J, 41x146
More

03220000A
fuse link 150 A
-Mersen-
600 V AC, fast acting
Class J, 41x146
More

03221000
fuse link 175 A
-Mersen-
600 V AC, fast acting
Class J, 41x146
More

03222000
fuse link 200 A
-Mersen-
600 V AC, fast acting
Class J, 41x146
More

03233000
fuse link 125 A
-Mersen-
600 V AC, time delay
Class J, 41x146
More

03234000
fuse link 150 A
-Mersen-
600 V AC, time delay
Class J, 41x146
More

03235000
fuse link 175 A
-Mersen-
600 V AC, time delay
Class J, 41x146
More

03236000
fuse link 200 A
-Mersen-
600 V AC, time delay
Class J, 41x146
More

Similar products

Find your contact

to the contact site

Wöhner GmbH & Co. KG
Elektrotechnische Systeme
Mönchrödener Str. 10
96472 Rödental

Order hotline (Germany)
+49 9563 751 161
order@woehner.de

Technical hotline (Germany)
+49 9563 751 260
support@woehner.com

Products Configurator Current metal surcharges folder for files