holder for cylindrical fuses, with LED

The picture may show a similar product.

Description

Part No.: 31299 000

AMBUS Panel

holder for cylindrical fuses, with LED

Class CC / 2P

30 A / 600 V

indication (LED) of a tripped fuse link

for mounting rail

System

Panel

Advantages of the product

large clamping range, also for two identical conductors (adjacent)
holder for label
with indicator for tripped fuse
any polarity for DC voltage

Product group 17
Subgroup 07
pack size 6
EAN 4021267312992
ECLASS 14.0 27142190
ETIM 5.0 EC002705
ETIM 8.0 EC002705
ETIM 10.0 EC002705

Approvals

Standards

IEC 60269-1:2006 + A1:2009 + A2:2014
IEC 60269-2:2013 + A1:2016, Fuse system J

UL 4248-1

UL 4248-4

Approvals

CSA , UL , CCC

for UL feeder circuits >250V

type number: AESCC

EAC Type: AES

UL file: E230163, UL category (for USA): IZLT https://www.ul.com

UL file: E230163, UL category (for Canada): IZLT7 https://www.ul.com

CSA file: 110285, CSA class: 6225-01 https://directories.csa-international.org

CCC certificate: 21107299296

Technical data

for fuse links size: Class CC
fuse links acc. to standard: UL 248-4
permitted power dissipation of the fuse-link: 4 W
Details IEC
Standards
IEC 60269-1:2006 + A1:2009 + A2:2014
IEC 60269-2:2013 + A1:2016, Fuse system J
Electrical data IEC
min. operating voltage AC: 110 V
min. operating voltage DC: 110 V

power dissipation of the article:

The power dissipation at a typical load of 80 % results to 0.4 W.

(The power dissipation at full load would be 0.6 W.)

Supplementary data IEC

The following values have been verified with tests under certain conditions. Please ask Wöhner for this conditions before designing your panel.

min. permitted operation temperature -40°C
indicator light
operating voltage range: 110 - 600 V AC / DC
Details UL
Standards
UL 4248-1
UL 4248-4
for UL feeder circuits >250V
suitable for field-installed conductors
Electrical data UL
rated current (UL): 30 A
rated voltage (UL) AC: 600 V
min. operating voltage AC: 110 V
rated frequency (UL): 50 / 60 Hz
rated voltage (UL) DC: 600 V
min. operating voltage DC: 110 V
for wires UL: Cu 60°C
SCCR: 200 kA
Mechanical data
W x H x D: 36 x 81 x 58
weight: 12.3 kg/100
poles: 2-pole
Mounting: for mounting rail
degree of protection: IP20
front degree of protection: IP20
Terminal points
cage clamp connection
screw drive: PZ2
wire stripping: 11 mm
min. cross-section: 0.75 mm²
max. cross-section: 25 mm²
Md min.: 2.0 Nm
Md max.: 2.5 Nm
Not suitable for aluminium cables !
  
min. cross-section UL: AWG 18
max. cross-section UL: AWG 4
torque (UL): 18 - 22 / 22 - 26 (AWG 6 - AWG 4) lb-in
for wires UL: Cu 60°C
  

connection of 2 wires (of same cross-section)
for applications acc. to IEC / EN:
Cu 0,75 - 10 mm²
all further details: as for connection of 1 conductor

connection of 2 wires (of same cross-section)
for applications acc. to UL / CSA:
Cu AWG 18 - AWG 6
all further details: as for connection of 1 conductor

 

Material properties
halogen-free: Yes

Application notes

Not suitable for aluminium cables !

The indicator light signals that the fuse has tripped, but only when the closed fuse-holder is under voltage.

permitted power dissipation of the fuse-link: 4 W
for UL feeder circuits >250V

Links (Prices, CAD data)

Downloads

Accessories

connection accessories

31561 000
comb-type busbar, 2-pole, bridge type, pitch 18 mm
100 A, 1 m long
25 mm²
More

Similar products

31296 000
AMBUS Panel
holder for cylindrical fuses
Class CC / 2P
30 A / 600 V
for mounting rail
More

Find your contact

to the contact site

Wöhner GmbH & Co. KG
Elektrotechnische Systeme
Mönchrödener Str. 10
96472 Rödental

Order hotline (Germany)
+49 9563 751 161
order@woehner.de