hybrid motor starter, 3-pole (36109)

The picture may show a similar product.

Description

Part No.: 36109 000A

MOTUS®CrossBoard

hybrid motor starter, 3-pole

electronic unit direct and reversing starter 0.075 - 0.6 A / switch for resistive loads 0.075 - 0.6 A

with CrossLink® interface

System

CrossBoard® 125A / 250A

Product group 21
Subgroup 01
pack size 1
EAN 4021267361099
ETIM 5.0 EC001037
ETIM 8.0 EC001037

Approvals

Standards

EN 60947-1:2015
EN 60947-4-2:2012
EN 61439-1:2012
EN 50581:2012
EN ISO 13849-1:2015

UL 60947-1

Approvals

UL , CCC , Atex

for UL feeder circuits >250V

type number: 36109.1

UL file: E360470, UL category (for USA): NLDX https://www.ul.com

UL file: E360470, UL category (for Canada): NLDX7 https://www.ul.com

CCC certificate: 2019010304252617

Type-Examination Certificate: PTB13AT3001

Technical data

Details IEC
Standards
EN 60947-1:2015
EN 60947-4-2:2012
EN 61439-1:2012
EN 50581:2012
EN ISO 13849-1:2015
Electrical data IEC
rated current (IEC): 0.6 A
rated voltage (IEC) AC: 500 V
min. operating voltage AC: 42 V
prosp. Kurzschlussstrom: 100 kA
resistive rated current: 0.6 A
inductive rated current: 0.6 A
trigger characteristic: Class 10A
set nominal current: Yes
min. load current: 0.075 A
max. switching frequency: 2 Hz
switching cycles: 30.000.000
safety level: SIL3
reply contact: 1 CO
rated frequency (IEC): 50 / 60 Hz
rated isolation voltage Ui AC: 500 V
rated surge voltage Uimp : 6 kV

power dissipation of the article:

The power dissipation at a typical load of 80 % results to 1.8 W.

(The power dissipation at full load would be 2.8 W.)

Supplementary data IEC

The following values have been verified with tests under certain conditions. Please ask Wöhner for this conditions before designing your panel.

min. permitted operation temperature -25
max. permitted operation temperature 70
min. permitted temperature for transport and storage -40
max. permitted temperature for transport and storage 80
Details UL
Standards
UL 60947-1
for UL feeder circuits >250V
Electrical data UL
rated current (UL): 0.6 A
rated voltage (UL) AC: 500 V
min. operating voltage AC: 42 V
rated frequency (UL): 50 / 60 Hz
SCCR unprotected max.: 5 kA
3 cycles (without OPD) @ 600 V AC
SCCR protected max.: 100 kA
SCCR: 100 kA with JDDZ fuse Class J 175 A / 600 V AC
Mechanical data
W x H x D: 22.5 x 160 x 120
weight: 50.9 kg/100
poles: 3-pole
degree of protection: IP20
vertical installation position: Yes
horizontal installation position: No
Terminal points
screw clamp connection
screw drive: 0,8x4
wire stripping: 8 mm
min. cross-section: 0.2 mm²
max. cross-section: 2.5 mm²
Md min.: 0.5 Nm
Md max.: 0.6 Nm
  
min. cross-section UL: AWG 24
max. cross-section UL: AWG14
torque (UL): 4,4 - 5,3 lb-in
Material properties
halogen-free: Yes

Application notes

permitted degree of polution: 2
for UL feeder circuits >250V

Links

Downloads

Accessories

spare parts

31567 000
replacement fuse for MOTUS®
Size 10x38
fuse 16 A for version 0.6 A and 2.4 A
10x38 gR
More

Find your contact

to the contact site

Wöhner GmbH & Co. KG
Elektrotechnische Systeme
Mönchrödener Str. 10
96472 Rödental

Order hotline (Germany)
+49 9563 751 161
order@woehner.de

Technical hotline (Germany)
+49 9563 751 260
support@woehner.com